Installation; Functional Description - Becker Centronic VarioControl VC470 Notice De Montage Et D'utilisation

Masquer les pouces Voir aussi pour Centronic VarioControl VC470:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Caution
Risk of injury by electric shock!
All electrical installations must be performed by an authorised electri-
cian!
During assembly please always ensure that cables cannot be damaged
during system operation. Any sharp edges which the cable comes into
contact with must be covered with suitable protective band. Damaged
wiring may be replaced by the manufacturer only.
If the VC470 is used to operate more than one drive, the drives must be
decoupled by relay controls. This does not apply to Becker drives with
electronic limit switches.
The switched current of the device must be observed at all times.
Mains 230 V / 50 Hz
1= N (blue)
= earth conductor (green-yellow)
2= L1 (black)
3= not required (brown)
Awning mode/ Venetian blind mode
You can toggle between awning and venetian blind mode.
Awning mode
After pressing a button, the awning travels in self-locking mode to the set final
position.
Venetian blind mode (factory setting)
In venetian blind mode, you can control the receiver in jog mode. If you press the
button for longer than 1 second, the venetian blind travels in self-locking mode.

Installation

4034 645 062 0

Functional description

Tubular drive
1= N (blue)
2= s black/
brown
= earth
conductor
3= t brown/
(green-
black
yellow)
Mounting strap
de
en
fr
nl
21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Centronic variocontrol vc470-ii

Table des Matières