Diagnostics; Receiver - SOMFY ROLLIXO io Manuel D'installation

Masquer les pouces Voir aussi pour ROLLIXO io:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Rollixo io

14 - DIAGNOSTICS

14.1 Receiver

Indicator light status
Meaning
Off
Functional installation
Waiting for an action/adjustment
Deactivation/activation in progress
Permanently lit
Installation fault/failure
Diagnostics
protection
Consequences
Actions
Diagnostics
Consequences
Actions
Diagnostics
Consequences
Actions
Diagnostics
Motor
Consequences
Actions
Diagnostics
Consequences
Actions
Diagnostics
Actions
Diagnostics
Consequences
Optical wired
safety edge
Actions
Copyright © 2014 SOMFY ACTIVITES SA. All rights reserved.
Indicator light status
Fall protection is not connected or there
is no bridge on the connector if fall
protection is connected to the shared
motor terminal
Fall protection triggered
No movement possible
Check the fall protection wiring (see
section 3.2).
Incorrectly wired motor
No movement possible
Check the motor wiring (see section 3.2).
Fall protection triggered (when fall
protection is connected to the shared
motor terminal)
No movement possible
Check the installation and replace the fall
protection.
Activated motor thermal protection
No movement possible
Wait around 10 minutes.
Faulty motor or fuse blown
No movement possible and integrated
lighting off
Check the condition of the fuse and
replace it if necessary (spare fuse
supplied, see section 2.2, point 14).
If the motor still does not work, replace it.
Waiting for motor adjustment
Set the motor end limits (see section 3.4).
Optical wired safety edge failure
Opening ok
Closing by pressing and holding down
the button within sight of the door
- Check the type of safety edge connected
(optical wired safety edge, dipswitch
no.4 set to OFF); if the connected wired
safety edge is resistive, move dipswitch
no.4 to ON.
- Check the safety edge wiring (see
section 7.3).
- Check that no radio safety edge
transmitter is stored in the receiver. If a
radio safety edge transmitter is stored in
the receiver, clear it (see section 12).
Diagnostics
Consequences
Resistive
wired safety
edge
Actions
Prog
Diagnostics
Consequences
Actions
Diagnostics
Consequences
Radio safety
Actions
edge
Diagnostics
Consequences
Actions
Diagnostics
Consequences
Actions
Indicator light status
Wired resistive safety edge failure
Opening ok
Closing by pressing and holding down
the button within sight of the door
- Check the type of safety edge connected
(wired resistive safety edge, dipswitch
no.4 set to ON); if the connected wired
safety edge is optical, move dipswitch
no.4 to OFF.
- Check the safety edge wiring (see
section 7.3).
- Check that no radio safety edge
transmitter is stored in the receiver. If a
radio safety edge transmitter is stored in
the receiver, clear it (see section 12).
Radio safety edge failure
Opening ok
Closing by pressing and holding down
the button within sight of the door
Request movement again and if the
problem persists:
- See radio safety edge transmitters for
diagnostics (see pages 14.2).
- Repeat the safety edge transmitter
programming procedure on the receiver
(see section 10).
Radio interference on the safety edge
transmitter
Opening and stopping ok
Closing by pressing and holding down
the button within sight of the door: the
closing movement will automatically
resume when the radio interference
disappears.
If a powerful radio system is present on
the site (infrared detector, TV transmitter,
etc.) and is transmitting on the same
frequency, the receiver will wait for the
transmission to end to before controlling
the door again.
End of life of the safety edge transmitter
batteries
Opening ok
Closing by pressing and holding down
the button within sight of the door
Safety edge transmitter low battery
indication.
If the fault persists, replace the safety
edge transmitter batteries.
Obstacle detection
Remove the obstacle by automatic partial
opening
Check that no obstacle is causing the
safety edge to detect.
and install one if necessary or rectify the
ground to make it smooth and even.
Prog
15