The motion sensor exhibits the most dependable detec-
tion behavior when the detection range is passed through
transversally and not frontally to the motion detector.
The listed detection range refers to an installation height
of 2.5 m.
• In order to make installation easier, you can use the
drilling template printed on the packaging.
• Hold the drilling template in place, mark hole loca-
tions, and drill holes with a diameter of 6mm.
• Press pins into place and screw on the lower part of
the housing.
• Insert the rubber grommet for the cable entry and feed
the connection wires through.
• The cable entry points must be absolutely water-proof.
• Make the electrical connection.
• Attach the front cap and screw together.
Electrical connection
Connect the wires and lamp wires as follows:
See wiring diagram
Phase L on luster terminal Brown
Neutral wire N luster terminal Blue
Connecting wire LS luster terminal Red
The motion detector needs 1 min (start-up time) for ope-
ration upon connection to the power supply.
red
blue
brown
Connection of consumers
High starting currents severely reduce the useful life of
relays. For this, follow the technical instructions of the
lamp or light manufacturer.
High inductive loads should be switched by means of an
additional relay or an additional contactor.
LS
N
230 V/
50 Hz
L
black
17