Rated voltage
Battery type
Degree of protection
Permissible ambient temperature
Type of mounting
Maximum emitted transmission output
Radio frequency
The maximum transmitter range on and in the building is up to 25 m, and up to
350 m in the open.
Problem
Drive is not functioning.
Drive not functioning, transmission
pilot light lights up.
Transmission pilot light flashes and
BATTERY appears in the display.
No reaction from transmitter after
changing batteries.
Astro program is not switching ac-
curately.
66 - en

Technical data

What to do if...?

Insert new batteries.
Insert batteries correctly.
Reduce distance from receiver.
Program transmitter.
Insert new batteries.
Press the RESET button.
Check the settings.
Set correct date.
Set correct city or exact degree of
latitude/longitude.
Switch off holiday function.
Adjust Astro shift.
3 V DC
LR03 (AAA)
IP 20
-10 to +55°C
Wall mounting
≤ 25 mW
868.3 MHz
Remedy