Preparing Furniture Doors; Furniture Door Dimensions; Connecting The Appliance; Electrical Connection - Bosch 800 Série Notice D'utilisation

Masquer les pouces Voir aussi pour 800 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Preparing furniture doors

Note:
When working on furniture doors, always observe
the following:
Select a furniture door thickness between at least 5/
8" (16 mm) and 3/4" (19 mm).
Always select a screw length which is shorter than
the thickness of the furniture door.
Always insert screws into the part of the furniture
door which is best able to handle the load.
Do not insert screws into fillings, or similar.
Do not insert screws into filters, decorative strips, or
similar.
Protect the furniture door surfaces against damage
during installation.

Furniture door dimensions

Key
A
Furniture door protrusion
B
Lower edge of furniture door
The specified furniture door dimensions apply for a
door gap of
/
" (4 mm).
5
32

Connecting the appliance

After installing the appliance, wait at least 8 hours until
the appliance is switched on. During transportation
the oil in the compressor may have flowed into
the refrigeration system.
Before switching on the appliance for the first time,
clean the interior of the appliance (see chapter
Cleaning the appliance).

Electrical connection

,
WARNING:
Avoid the risk of an electric shock!
,
WARNING:
Insert into a grounded 3-phase socket. Never
remove grounding phase. Do not use any
adapters. Do not use any extension cables.
,
WARNING:
Non-compliance with these instructions may
result in death, fire or an electric shock.
Improper connection of the protective conductor
may result in an electric shock. If you are in
doubt whether the appliance has been grounded
properly, have the appliance tested by
a qualified electrician or service technician.
Do not use extension cables or distributors. This
appliance must be connected to a permanently
installed socket.
The socket must be near the appliance and also freely
accessible following installation of the appliance.
The appliance complies with protection class I.
Connect the appliance to 115 V/60 Hz alternating
current via a correctly installed socket with protective
conductor. The socket must be fused with a 10 to 16 A
fuse.
The appliance comes with a UL registered 3-wire power
cord. The appliance requires a 3-pole socket.
Please observe the following table with regard to this:
Appliance
Maximum simulta-
neous load
Fridge-
6.0 amps
freezer
Check on the rating plate whether the indicated voltage
and current type correspond with the values of your
power supply. The location of the rating plate can be
found in the chapter entitled Customer service.
,
WARNING:
Never connect the appliance to electronic
energy saver plugs.
Our appliances can be used with mains and
sine-controlled inverters. Mains-controlled
inverters are used for photovoltaic systems
which are connected directly to the national grid.
Sine-controlled inverters must be used for
isolated applications (e.g. on ships or
in mountain lodges) which are not connected
directly to the national grid.
en-us
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

B0ib sérieB09ib80nsp

Table des Matières