Testing The Rccb - ABL Wallbox eMH2 Mode D'emploi

Masquer les pouces Voir aussi pour Wallbox eMH2:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40

Testing the RCCB

To ensure the continuing safe operation of the wallbox, the function of the RCCB must be tested regularly
according to locally applicable regulations (e.g. every 6 months in Germany): For this purpose, the RCCB
has a push button with which to initiate the test function.
Proceed as follows to test the RCCB:
1
Open the housing cover of the wallbox with
the housing cover key and put it aside.
2
Open the access flap of the internal electronic
components cover.
3
Locate and press the push button engraved T
or marked Test.
y The RCCB must now trip and flick its pivot
lever into the centre position.
4
Now flip the pivot lever first to the 0 position
and then back to the I position.
5
Close the access flap, hook the housing cover
onto the upper edge of the housing base and
lock it using the housing cover key.
Danger
Dangerous electrical currents
Should the RCCB malfunction during testing, you must not continue to operate the wallbox under any
circumstances!
ƒ Contact a qualified specialist electrical contractor to have the error resolved.
Wallbox eMH2 – Testing the RCCB
|
27

Publicité

Table des Matières
loading

Table des Matières