11�2 Read The Set Parameters; Technical Data; Troubleshooting - Autosen AS005 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

> The display changes, the indicator LEDs indicate the current display unit�
> After 30 seconds the display changes to the standard display�
11.2 Read the set parameters
► Briefly press [●]
► Press [▼] to select the parameter.
► Briefly press [●]
> The currently set value is displayed for 30 s� Then the unit returns to the pro-
cess value display�

12 Technical data

Technical data and scale drawing at www�autosen�com�

13 Troubleshooting

The unit has many self-diagnostic options� It monitors itself automatically during
operation�
Warnings and error states are displayed, even when the display is switched off�
Error indications are also available via IO-Link�
Display Type
Err
Error
No display Error
PArA
Error
Loc
Warning
C�Loc
Warning
S�Loc
Warning
Description
• Unit faulty / malfunction�
• Supply voltage too low�
• Setting [diS] = OFF�
Parameter setting outside the
valid range�
Setting pushbuttons on the
unit locked, parameter change
rejected�
Setting buttons on the unit
temporarily locked, parameter
setting via IO-Link communica-
tion active�
Setting buttons locked via
parameter software, parameter
change rejected�
Troubleshooting
► Replace the unit�
► Check the supply voltage�
► Change the setting [diS] →
10�4�1�
► Check parameter setting�
► Unlock the unit → 10.1.3.
► Finish parameter setting via
IO-Link communication�
► Unlock the unit via IO-Link
interface using the parame-
ter setting software�
UK
77