NOTE: Key lock is not deactivated by switching off the pump.
The power consumption meter cannot be reset to the factory
settings when key lock is activated. Key lock is not activated
automatically, e.g. after a set period of time has passed.
8.8
Operation
Note: All settings and displays are retained if the mains supply
is interrupted.
Resetting the power consumption meter
• In pump standby mode, press the button for 10 seconds. The
power consumption meter sets itself to zero after the current
meter reading on the display has flashed five times.
Restoring the factory settings
• When the pump is in standby mode, press the button for
20 seconds, all LED elements light up for 2 seconds. The factory
setting (delivery condition) of the pump is restored and the
power consumption meter in the display is at zero.
9 Maintenance
DANGER! Danger of death!
A fatal shock may occur when working on electrical equip-
ment.
• The pump should be electrically isolated and secured against
unauthorised switch-on during any maintenance or repair
work.
• Any damage to the connecting cable should always be recti-
fied by a qualified electrician only.
WARNING! Danger due to strong magnetic field!
Inside the machine there is always a strong magnetic field
that can cause injury and damage to property in the event of
incorrect dismantling.