• If the unit is used for sewage containing faeces, the valid regulations for potentially
• Never introduce solids, fibrous substances, tar, sand, cement, ash, coarse paper, paper
• Improper use and overstraining lead to material damage to the product.
• The maximum possible inflow must always be less than the volume flow of a pump at

5 Product information

5.1 Type key
Example:
DrainLift
M
2
/8
(1~)
5.2

Technical data

Connected voltage
Connection version
Power consumption P
Nominal current
Mains frequency
Installation and operating instructions Wilo-DrainLift M2/8
NOTE: During installation and operation, be sure to observe the nationally and regionally
valid standards and regulations.
The specifications in the operating instructions of the switchgear are also to be observed.
DANGER! Risk of explosion!
Sewage containing faeces in collection reservoirs can lead to gas accumulation, which
can ignite as a result of improper installation and operation.
explosive areas are to be observed.
WARNING! Health hazard!
Because of the materials used, the pumps are not suitable for pumping potable water!
Contaminated sewage is a health hazard.
CAUTION! Risk of damage!
Inappropriate materials in the system can cause damage to the product.
towels, cardboard, debris, rubbish, animal waste, grease, or oil into the drains!
If greasy sewage should accumulate, a grease trap is to be installed.
the respective duty point.
Application limits
The unit is not designed for permanent operation!
The specified maximum volume flow applies for intermittent operation (S3 – 15 %/80 s,
i.e. max. 12 s operating time, min. 68 s idle time).
The unit may switch on a maximum of 45 times per hour per pump. The running time of the
pump may not exceed 12 s, including the run-on time (run-on time = pump running time
after the end of pumping water). The operating time and run-on time (if required) should
be set as short as possible.
The geodesic delivery head may not be more than 6.5 mWS.
WARNING! Risk of burns!
Depending on the operating status of the installation, the entire pump can become very
hot. Touching the pump can cause burns.
WARNING! Danger due to overpressure!
If the lowest suction head is more than 5 m, this will cause overpressure in the reservoir
should the installation malfunction. If this happens, there is a risk that the reservoir will
burst.
In case of malfunctions, the inlet must be blocked off immediately!
The intended use includes complying with these instructions.
Any other use is considered outside the intended use.
DrainLift M 2/8 (1~)
Sewage lifting unit
Size
2 = Double-pump system
Maximum delivery head [m] when Q=0 m³/h
1~: Single-phase version
3~: Three-phase version
1
[V]
1~230 +10/-5 %, 3~400 ± 10 %
1~: Switchgear with cable and shock-proof
plug
3~: Switchgear with cable and CEE plug
[kW]
See unit name plate
[A]
See unit name plate
[Hz]
50
English