Olsberg Libera plus 43/118 Mode D'emploi page 27

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The temperature difference between the switch-on
and switch-off temperatures can be selected between
3° to 6°.
Example:
Room temperature SET T. ROOM
STARTTEMPERATUR
The unit switches off when the room temperature is
22°C and switches on again at 16°C.
If standby mode is OFF, then the unit does not switch
off when the set temperature is reached, but instead-
continues to heat at the lowest power setting.
Press the two arrow buttons
same time.
The message MENÜ SET WORK appears on the
display.
Press the
button 2 times.
The message SET STOVE appears on the dis-
play.
Press the ON button to get into the menu.
Press the
button down until the message
STANDBY appears.
Press ON to get to the settings.
The current setting will flash.
Use the
+
buttons to select ON or OFF.
Confirm with ON and continue on to
STARTTEMPERATUR.
Use the
+
buttons to enter the desired
STARTTEMPERATUR (switching difference is 3
– 6°C) and confirm with ON.
To exit the menu:
Press the OFF button to exit the STANDBY
menu.
Press the OFF button to exit the SET STOVE
menu.
10.4.6 STATUS BUZZER
This enables the activation or deactivation of the
warning signal.
If an alarm message is displayed, the warning signal
remains even if the buzzer is deactivated.
Press the two arrow buttons
same time.
The message MENÜ SET WORK appears on the
display.
Press the
button 2 times.
The message SET STOVE appears on the dis-
play.
Press the ON button to arrive at the menu.
Keep the
pressed until the message STATUS
BUZZER appears.
Press the ON button to get into the menu.
Use the
+
buttons to select ON or OFF.
Confirm with ON.
= 22°C Set
= 16°C
+
at the
+
at the
- 25 -
To exit the menu:
Press the OFF button to exit the STATUS
BUZZER menu.
Press the OFF button to exit the SET STOVE
menu.
10.4.7 NIGHT TIME REDUCTION
This makes it possible to set the temperature to
which the room is to be heated even in the off phase
of the unit.
The switching difference is basically 3K.
Example:
The set night time temperature is 10°C.
The unit switches on when the room temperature is
7
and switches off again at 10 .
The night time temperature can be set from 3 - 20°C
or OFF.
Press the two arrow buttons
same time.
The message MENÜ SET WORK appears on the
display.
Press the
button 2 times.
The message SET STOVE appears on the dis-
play.
Press the ON button to get into the menu.
Press the
button down until the messag SET
NIGHT T. appears.
Press the ON button to get into the menu.
The active operating mode flashes.
Use the
+
buttons to set the value of the
desired night time temperature to between 3 –
20°C or deactivate the function with OFF.
Confirm with ON.
To exit the menu:
Press the OFF button to exit the SET NIGHT T.
menu.
Press the OFF button to exit the SET STOVE
menu.
10.4.8 BLOCK BUTTONS
This enables blocking of the keypad of the operating
panel.
Press the two arrow buttons
same time.The message MENÜ SET WORK ap-
pears on the display.
Press the
button 2 times.
The message SET STOVE appears on the dis-
play.
Press the ON button to enter the menu.
Hold the
button down until the message
KEYLOCK appears.
Press the ON button to get into the menu.
The active operating mode OFF flashes.
Use the
+
buttons to select ON or OFF.
Press ON to confirm.
+