Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The chimney stove is coated with a high-quality
temperature resistant lacquer, which achieves its
final hardness after the first firing.
- Therefore, do not place anything on the chimney
stove and do not come into contact with the sur-
faces, because this could cause damage to the
finish.
The chimney stove should only be operated with
the combustion chamber door closed.
Do not remove hot ashes. Ashes may only be
stored in fire-resistant, unflammable containers.
Important: The surfaces will be hot!
The precautionary measures regarding combus-
tion air supply may not be changed.
When the stove is new (or when the container is
completely empty) it might not light because the
pellet loading screw needs a few minutes to fill
up and feed the pellets.

8.3 Operation panel

All settings for heating operation, and service and
maintenance programs are entered into the operation
panel.
The commands are entered using the 4 buttons on
the control panel.
All operation parameters are shown on the display.
ok OFF
P=5 V=5 T=15°/22°
Olsberg
X
The 4 buttons have the following functions:
ON (ok)= start/change confirmation
OFF (x)
= off/ends the entry mode/changes to
higher operation levels
= changes to next level / increases
the displayed value
= changes to next level / decreases
the displayed value
8.4 Ignition process
To ignite the unit, press and hold down the ON
button for several seconds.
The message WAIT FLAME will appear in the
display. During this period, the pellets in the
combustion pan are being ignited automatically.
ok Wait/Flame
Olsberg
X
12:45
- 21 -
After the pellets have been ignited, the message
PRESENT FLAME appears.
As soon as the temperature for correct burn-off is
attained, the unit switches to heat operation.
8.5 Heat operation
After ignition, the message WORK/MODULING
appears in the display.
ok WORK
P=5 V=5 T=15°/22°
Olsberg
X
Heat operation is automatically regulated accord-
ing to the entered settings.
The following operation parameters appear in the
display along with WORK:
P = heat setting level
V = convection ventilation level
T = actual room temperature / set room tem
perature)
The display of the operation parameters can be pre-
sented in two different ways, ROLLING or SHORT.
ROLLING:
The operating paramaters appear one after the other
in the display.
SHORT:
All operating paramaters appear simultaneously in
the display (as shown).
Factory setting is ROLLING.
After the desired room temperature has been
reached, the following message appears in the dis-
play, depending on the selected display type:
For Laufband:
THERMOSTAT ON.
For Komplett:
The displayed temperature T values are blinking.
The message MODULAR OPERATION will also
appear.
8.5.1 Menu point Power
This defines the desired heating performance for the
possible levels 1-5 and A (automatic).Settings:
When POWER appears in the display in the scrolling
mode, press the
button to increase the value, and
the
button to decrease the value.
In complete mode, the settings are entered in the
SET WORK menu (see point 10.2).
12:45

Publicité

Table des Matières
loading

Table des Matières