Qlima GH 438 B Manuel D'utilisation page 64

Chauffage à gaz
Masquer les pouces Voir aussi pour GH 438 B:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
GB
Model identifier(s): GH438B
Indirect heating functionality: [no]
Direct heat output: 3.8 (kW)
Indirect heat output: N.A. (kW)
Fuel
Select fuel type
Item
Heat output
Nominal heat
output
Minimum heat
output
(indicative)
Auxiliary electricity consumption
At nominal heat
output
At minimum
heat output
In standby
mode
Permanent pilot flame power requirement
Pilot flame
power requirement
(if applicable)
Contact details
(*) NOx = nitrogenoxides
This product is not suitable for primary heating purposes
Energy efficiency class: Class A
Direct heat output: 3.8kW
Energy efficiency index: EEI=89%,
Refer to instruction manual for the assembly, installation, maintenance, disassembly, recycling and/ or disposal at end-
of-life.
The afore described gas heater is in conformity with following EC directive and Regulations:
- Gas Appliances Regulation (EU) 2016/426 (GAR)
- Commission Delegated Regulation (EU) 2015/1186 & 2015/1188
The following harmonised standards have been applied:
- EN449:2002 + A1:2007
1
SUPPLIER
2
MODEL
3
ENERGY EFFICIENCY CLASS
4
DIRECT HEAT OUTPUT
5
INDIRECT HEAT OUTPUT
6
ENERGY EFFICIENCY INDEX
USEFUL EFFICIENCY AT NOMINAL HEAT
7
OUTPUT
OTHER
ASSEMBLY,
4
8
MAINTAINANCE OF LOCAL SPACE HEATER
9
OTHER PVG MODEL
64
Information requirements for gaseous/liquid fuel local space heaters
[gaseous]
Symbol Value
Unit
Item
Useful efficiency (NCV)
Useful efficiency at
P nom
3.8
kW
nominal heat output
Useful efficiency at
P min
N.A.
kW
minimum heat output
(indicative)
Type of heat output/room temperature control (select one)
el max
N.A.
kW
single stage heat output,no room temperature control
el min
N.A.
kW
two or more manual stages, no room temperature control
el SB
N.A.
kW
with mechanic thermostat room temperature control
with electronic room temperature control
with electronic room temperature control plus day timer
with electronic room temperature control plus week timer
Other control options (multiple selections possible)
room temperature control, with presence detection
room temperature control, with open window detection
with distance control option
with adaptive start control
with working time limitation
with black bulb sensor
P pilot
0.14
kW
PVG Holding BV, Kanaalstraat 12c, 5347KM Oss, The Netherlands
PRODUCT FICHE
PRECAUTIONS
REGARDING
INSTALLATION
Space heating emissions ( * )
NOx
77.9 [mg/kWh input ] (GCV)
G30
Symbol
η th,nom
η th,min
PVG HOLDING B.V.
GH438B
A
3.8 kW
/
88.60%
100.00%
OR
refer to user manual
Value
Unit
100
%
N.A.
%
[no]
[yes]
[no]
[no]
[no]
[no]
[no]
[no]
[no]
[no]
[no]
[no]

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières