Annexe - Endress+Hauser Liquisys M CCM223 Manuel De Mise En Service

Masquer les pouces Voir aussi pour Liquisys M CCM223:
Table des Matières

Publicité

Liquisys M CCM223/253
Zero calibration
CALIBRATION
(only if A1 = 120)
zero
(CCS120)
no;
Enter
DPD value
CALIBRAT
Cl 2 / ClO 2
Value of last cal.
C
MEAS. VALUE
DISPLAY
with
TEMPERATURE
READING
in °C
Select sensor
140;
141; 240; 241;
963; 120
SETUP 1
A
PH compensation
Off;
SETUP 2
B
Cont. switch-off
by current input
Off;
CURRENT INPUT
Z
Select current output
Output1;
CURRENT OUTPUT
O
Select contact type
Latch = latching c.
Momen
=
ALARM
F
Endress+Hauser
13

Annexe

Calibration status is
displayed
yes
o.k.
Exxx
C15
C14
Zero calibration
(only if A1 = 120 or 963)
no;
yes
C11
C12
Meas. value display
Temperature reading in °F
1st error displayed
(if present)
Select display unit
mg/l
; ppm; ppb
A1
A2
Manual
pH compensation
last comp. value
Manu
pH 4.00 ... 9.00
B2
B3
Delay for cont.
switch-off curr. input
Input
0 s
0 ... 2000 s
Z1
Z2
Select meas. unit for
2nd current output
Output2
°C
; mg/l; ppm; ppb; Contr
O1
O2
Select unit of alarm
delay
momentary c.
min;
s
F1
F2
Store calibration
Operating matrix versions EK and ES
result
no; new
yes;
C15
Slope is
Calibration status
displayed
is displayed
100%
min. 25% (3%)
max. 500%
o.k.
Exxx
C13
Meas. value display
Meas. value display
no temp. display
Sensor current in nA
Other errors are
displayed
(up to max. 10 errors)
Controller switch-off
Delay for controller
by sample stream
switch-off sam. stream
Off;
INS
0 s
0 ... 2000 s
A3
Enter correct
Enter temperature
process temperature
difference (offset)
current meas. value
current offset
0 ... 50 °C
–5.0 ... + 5.0 °C
B4
Delay for cont.
Sw.-off limit value
sw.-on current input
for current input
0 s
0 ... 2000 s
50%
0 ... 100%
Z3
Select table
options
read
edit
Tab = Table
O3(3)
Enter simulation
val.
current value
0 ... 22.0 mA
sim = Simulation
O3(2)
Select current range
4–20 mA;
0–20 mA
lin = linear
O3(1)
Alarm delay
Define
0 min (s)
error current
0 ... 2000 min (s)
(dep. on F2)
22 mA;
2.4 mA
F3
Store
calibration
yes;
no; new
C14
C15
Meas. value display
Meas. value display
Current input in %
Current input in mA
Only display switchover!
Delay for contr.
swi.-on sam. stream
0 s
0 ... 2000 s
ext.Hold
A4
A5
B5
Sw.-off direction
Feedforward control
for current input
Low;
High
Z4
Z5
Enter no. of
table pairs
1 ... no. Table pair
1
1 ... 10
O331
O332
O321
Enter 0/4 mA value
Enter 20 mA value
0.00;
0 ... 20 (5) mg/l
2.0 (0.5);
0 °C;
0 ... 50 °C
50 °C;
O311
O312
Select error number
1
1 ... 255
F4
F5
Annexe
Select
digital input 1
Clean trig.
A6
to PID cont.
Off;
lin = linear
Z6
Select
table pairs
1
asign
O333
0 ... 20 (5) mg/l
0 ... 50 °C
O313
Enable alarm
contact
yes;
no
F6
A0002633-FR
123