Programming system security
70
71
72
5 - 10
Programming system security
76
00
Programming the door activity alarm
80
1
80
0
56
#
After the wrong code has been entered 10 times, the
device locks out access for 30 seconds..
#
After the wrong code has been entered 10 times, the de-
vice switches contact "DURESS" to ground. The device
remains in this state until user code 1 is entered and the
# key is pressed. You can connect a suitable telephone
dialler, a transistor switch or similar device to this con-
tact. Be sure to stay within the loading specifications
of this output
#
The number of times a wrong code can be entered can
be set to a value between 5 and 10. After the specified
number of wrong code entries, the device locks out ac-
cess for 15 minutes.
This lockout can be removed prematurely by entering
the master code.
#
Codes can be wrongly entered any number of times. No
lockout period.
#
Active Alarm after forceful opening (without access
code or using the door opener) the connection between
the terminal "(-) GND" and terminal "DOOR SENS".
#
No alarm after opening the connection between the ter-
minal "(-) GND" and terminal "DOOR SENS".