Technical data

General Data

4
Technical data
General Data
Field
Order designation
PUO ID number
Communication profile
(DIN 19245 part 1 and part 3)
Communication medium
Drive profile
Network topology
PROFIBUS node
Baud rate [kbps]
Process data words
DP user data length
Max. number of nodes
Max. cable length per bus
segment
Communication time
External DC voltage supply
48
Values
E82ZAFPC010
0x00DA
hex
PROFIBUS-DP
RS485
DRIVECOM profile "Power Transmission 20", can be switched off
Without repeater: line
With repeater: line or tree
Slave
9.6 ... 12000 (automatic detection)
1 word ... 10 words
(16 bits per word)
4 parameter data words +
1 ... 10 process data words
Standard: 32 (= 1 bus segment)
With repeater: 125
1000 m (depending on the baud rate and cable type used)
Sum of the cycle time and the processing time in the fieldbus
nodes. The times are independent of each other.
Processing time in the controller:
– Parameter data: approx. 30 ms + 20 ms tolerance
– Process data: approx. 3 ms + 2 ms tolerance
+24 V DC ±10 %, max. 80 mA
EDK82ZAFPC-010 DE/EN/FR 6.0