Water Connection; Electrical Connection - Ndustrio 091CP1E Manuel D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

WATER CONNECTION

To make the connection, connect the mains line to
the appliance's connection pipe, fitting a shut-off
tap (A), to allow the water supply to be cut off when
necessary. Easily accessible filters must be fitted
downstream of the tap.
Caution - warning
The appliance must be supplied with drinking
water having the characteristics shown in the
table.
Description
Pressure
pH
Conductivity
Hardness
Salt and metallic ion
content
Chlorides
Sulphates
Iron
Copper
Manganese
(*) If the intake pressure exceeds 3 bar fit a pressure reduc-
er.

ELECTRICAL CONNECTION

IT
Important
The connection must be made by author-
GB
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The ap-
DE
pliance is supplied with operating voltage
400V/3N (230V/3 available on request) (see
FR
Connect the appliance to the
ES
mains electricity supply as fol-
lows.
1 - If not already present, in-
stall a circuit-breaker (A)
with overload cutout and
differential safety breaker
close to the appliance.
2 - Open the hatch (B).
3 - Undo the screws (C) to re-
move the guard (D).
English
Value
150÷300 kPa (1,5÷3 bar) (*)
7÷7.5
< 200 mS/cm
9÷13°f (5÷7°d, 6.3÷8.8°e,
90÷125 ppm)
< 30 mg/l
< 40 mg/l
< 0,1 mg/l
< 0.05 mg/l
< 0,05 mg/l
A
- 16 -
C
attached wiring diagrams). Specify the cor-
rect voltage for your device; it cannot be
modified after purchase.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
B
D
C
IDM-39615601500.tif
E
IDM-39615601600.tif

Publicité

Table des Matières
loading

Table des Matières