Voltage converter installation

Install the power inverter with suitable screws (not included):
in sturdy and even locations,
on clean, dry and non-flammable surfaces,
in well ventilated areas.
please be sure not to cover the vents.

Remote control module installation

Mount the remote control module in a safe and accessible location using suitable screws (not included). unwind the
entire remote control module (14) cable and plug the connector into the jack (11).

Connection to the power source

Caution!
as for how to connect the cables to the car electric system of your car, we strongly recommend you have this done by
a qualified technician. Modern cars boast very complicated electric panels. It might be hazardous for a non qualified
person to deal with such connections. a erroneous connection might damage your car and put you and people around
in danger.
Once connected the unit may sound an alarm, which is normal.

To a car battery

Warning!
risk of short circuits! always observe the correct polarity. avoid short circuiting the battery poles.
1. unscrew the red and black terminal screw at the back of the device.
2. place the red cable with the lug (15) and the washer onto the red terminal (2) and screw tight with the red terminal
screw.
3. place the black cable with the lug (14) and the washer onto the black terminal (1) and screw tight with the black
terminal screw.
4. Connect the red cable with the ring lug/clamp (13, 15) to the positive battery terminal (marked "p" or "+") .
5. Connect the black cable with the ring lug/clamp (12, 14) to the negative battery pole "marked "n" or "-").
Warning!
risk of electric shock in the event of a defect in the unit without the earth connected.
6. Connect the earth connector (4) to the available earth system (e.g. vehicle body or, for stationary use, the potential
equalisation bar or ground spike) using a suitable cable (not included).

uSe

Attention!
Some external devices, especially radios and/or other audio and chargeable devices can damage the power inverter
and/or the connected external appliance. Check to see whether the external appliance connected to the power inverter
"hums", overheats or heats excessively up in the first few minutes. If this is the case, disconnect the external appliances
and all cables immediately. In this case the external appliance are incompatible and cannot be operated with each
other. If anything should be unclear, consult the dealer of the external appliance.
you may use both 230 V sockets (6) and the uSB port (10) simultaneously. The total rated voltage for both devices
connected to the 230 V socket and the uSB port must not exceed the rated power of the voltage converter (see "Tech-