Using the device

MR07, MRR07
➤ Connect the red cable to the positive pole of the battery.
➤ Connect the black cable to the negative pole of the battery.
I
NOTE
The red/yellow cable is the starter cable for the device. When the
red/yellow cable is switched to 12 V, the device is switched on.
➤ Connect the red/yellow cable to a switch (not included in the supply).
➤ Connect the other side of the switch to the positive connection.
MH07
➤ Connect the positive pole of the battery to the positive socket terminal block.
➤ Connect the negative pole of the battery to the negative socket terminal block.
7
Using the device
A
NOTICE!
The interior temperature of the device is affected by the ambient
temperature.
• MR07 and MRR07 only: Observe that the set fixed temperature of
5 °C is fallen below, if the ambient temperature sinks to below 4 °C.
• Only MH07: Observe that the set fixed temperature of 37 °C is
exceeded, if the ambient temperature rises to above 37 °C.
I
NOTE
Before using the device for the first time, clean it inside and out with a
damp cloth for hygienic reasons (see also chapter "Cleaning and main-
tenance" on page 16).