CHARGING THE BATTERY
Open the seal underneath the battery.
12.2.1
BAT TE RY STATUS INDICATOR
To activate the status indicator press
12.3.1
the on/off button.
76 % - 100 %
51 % - 75 %
26 % - 50 %
11 % - 25 %
0 % - 10 %
ERROR CODES
Deep discharge > Charge the battery
Temperature problem > Return the battery to a normal operating environment
Short circuit due to foreign object > Remove the foreign object
Contact YT: service@yt-industries.com
The battery has been in use for 5 years or has reached the end of its
predetermined lifespan. Contact YT: service@yt-industries.com
OFF TH E BIK E
Insert the plug of the charger all the way into
12.2.2
the charging port of the battery. Make sure
to close the cover after charging the battery,
to prevent water ingress and to prolong the
service life of your battery.
CHARGER STATU S INDICAT OR
Red LED
= charging
12.3.2
Green LED
= charged
BATTERY CHARGING TIME
100 % ~ 3,5 - 4 hours
90 % ~ 3 hours
60 % ~ 2 hours
30 % ~ 1 hours
y t 4 9