Maintenance And Service; Inspection And Maintenance Intervals - HEROSE 4182 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 49
7

Maintenance and service

7.1
Safety during cleaning
Take note of the specifications in the safety data sheet and the general occupational health and
safety rules if degreasers are used for process-related reasons for the cleaning of bearing parts,
unions and other precision parts.
7.2
Maintenance
The maintenance intervals must be defined by the user according to the operating conditions.
The recommendations for the functional checking of the valves are to be taken from section 7.2.1
"Inspection and maintenance intervals" in these operating instructions.
7.2.1

Inspection and maintenance intervals

Inspection
Inspection
Functional testing
External inspection
Internal inspection
Hydraulic testing
Operating instructions
Recommended intervals
Interval
During start-up
Annually
Every 2 years
Every 5 years
Every 10 years
herose.com
Scope
Visual inspection
of the valve for damage;
of the valving marking for legibility;
Leak-tightness
between body and spring cover
of the connections
Check of the operating pressure set point.
Check of the operating pressure set point
including a visual inspection.
Function and tightness test including visual
check.
Replacement of all sealing elements, including a
function and tightness test as well as a visual
inspection.
Replacement of all sealing elements, including a
function, leak and pressure test as well as an
inspection.
25

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

4186

Table des Matières