Wiring Plan M12 X 1 Plug Connector - Balluff BMD 1L K Série Notice D'utilisation

Sonde de mesure tige et câble avec qualification sil
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Electronics and terminal
compartment
4...20mA
+
( )
1
Fig. 13: Electronics and terminal compartment - single chamber housing
1
Voltage supply, signal output
2
For display and adjustment module or interface adapter
3
For external display and adjustment unit
4
Ground terminal for connection of the cable screen
5.4

Wiring plan M12 x 1 plug connector

The illustration shows the structure and the assigned pins of the plug
connector. The table shows the assignment of the individual contact
pins to the terminals of the sensor electronics.
Fig. 14: Con guration plug connector M12 x 1 - 4
1
2
Fig. 15: View to plug connector 4
Voltage supply/Signal output
Contact
Colour, connection ca-
pin
ble in the sensor
1
Green
2
Free
3
Black
4
Red
5 Connecting to power supply
1
2
5
6 7 8
(-)
20 mA/HART
Terminal, elec-
tronics module
Free
Terminal 2
Terminal 1
2
3
4
20 mA/HART sensor
4
3
Function/Po-
larity
Screen
Free
Power supply/-
Power supply/+
25