Télécharger Imprimer la page

Job Function; Additional Functions - LORCH BasicPlus Manuel D'utilisation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 114

Additional functions

13

Job function

In a job, all the parameter settings for a welding process/oper-
ating mode are saved.
Reading in a job
 Hold the NFC card with the saved job against the NFC read
area of the device.
9 The welding process and all the parameter settings are
transferred to the device.
The welding process of the job must also be
i i
available on the welding device to be trans-
ferred to.
14
Additional functions
Control panel brightness
‰ This function can be used to set the brightness of the com-
plete control panel.
 Press the "Minus" A5 and "Plus" A11 buttons simultane-
ously for 2 sec.
9 The brightness is displayed in the "Dynamics" display A9.
 Increase or reduce the brightness by pressing the "Minus"
button A5 or the "Plus" button A11.
Gas test
 Press the Gas test button A14.
9 The Gas test LED A15 lights up and the solenoid valve
switches.
‰ The gas supply can be checked/adjusted. The function re-
mains active for 30 seconds and is then ended automati-
cally. The gas test can be aborted by pressing the Torch
button or by pressing the Gas test button again.
Fan test
 Turn on the equipment using the main switch 11.
9 The fan starts up briefly for a function check.
User Interface test
 Press the Crater fill A2 and Gas test A14 buttons simultane-
ously for 2 secs.
9 All the LEDs on the control panel light for approx 5 sec.
02.20
909.3049.9-03
- 31 -

Publicité

loading