V2 CITY1-EVO Guide Rapide page 29

Masquer les pouces Voir aussi pour CITY1-EVO:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
PARAMETER
VALUE
SEnS
1 - 10
no
FinE
no
Si
DESCRIPTION
Obstacle Sensor
This menu allows the sensitivity adjustment of the obstacle sensor
over 10 levels
The higher is the setup value, the prompter will be the control unit
intervention if there is any obstacle.
WARNING: apart from any setup sensitivity value, this system
will detect an obstacle only if the door is stopped; therefore,
no obstacle braking the door without stopping it will be
detected.
Obstacle detection will be performed only if the door moves at
a normal speed. Both doors will stop and they will be given the
command to go backwards for 3 seconds, to take out the obstacle
detected.
The following Start command will let the former door motion start
StoP
again (if the parameter
the opposite direction). In case the slowing down phase has already
begun, no obstacle will be detected and this kind of situation cannot
be considered as dangerous since the motor, when working according
to its slowing down function, will push the obstacle with a very low
pressure
Function deactivated
End of Programming
This menu allows to finish the programming (both default and
personalized) saving the modified data into memory.
You must exit from programming mode through this menu item if you
do not want to lose your configuration.
It does not exit from the program menu
It exits from the program menu by storing the setup parameters
invE
=
movement starts again in
- 27 -
AntE SCor
MEMO
5
5
no
no

Publicité

Table des Matières
loading

Table des Matières