V2 CITY1-EVO Guide Rapide page 24

Masquer les pouces Voir aussi pour CITY1-EVO:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
2 MOTORS
(LIMIT SWITCHES OR SENSOR OF OBSTACLES IS ENABLED)
1. Door 1 is opened for a few
seconds
2. Door 2 is closed until the limit
switches comes into action, or
the sensor of obstacles detects
that the door is locked
3. Door 1 is closed until the limit
switches comes into action, or
the sensor of obstacles detects
that the door is locked
4. An opening manoeuvre for
each door is carried out, the
operation ends when the limit
switches comes into action, or
the sensor of obstacles detects
that the door is locked
5. A closing manoeuvre for
each door is carried out, the
operation ends when the limit
switches comes into action, or
the sensor of obstacles detects
that the door is locked
6. The detected parameters are stored and the unit is ready for
use
1 MOTOR
(LIMIT SWITCHES OR SENSOR OF OBSTACLES IS ENABLED)
1. The door is closed until the limit
switches comes into action, or
the sensor of obstacles detects
that the door is locked
2. An opening manoeuvre is
carried out, the operation ends
when the limit switches comes
into action, or the sensor of
obstacles detects that the door
is locked
3. A closing manoeuvre is carried
out, the operation ends when
the limit switches comes
into action, or the sensor of
obstacles detects that the door
is locked
4. The detected parameters are stored and the unit is ready for
use
2 MOTORS
(NO LIMIT SWITCHES AND SENSOR OF OBSTACLES IS
DISABLED)
ATTENTION: in this case the limits of the run must be signalled
with a START order
1. Door 1 is opened for a few
seconds
2. Door 2 is closed until the unit
receives a START order
3. Door 1 is closed until the unit
receives a START order
4. An opening manoeuvre is
carried out for each door, the
operation ends when the unit
receives a START order (the first
START stops door 1, the second
START stops door 2)
5. A closing manoeuvre is
carried out for each door, the
operation ends when the unit
receives a START order (the first
START stops door 2, the second
START stops door 1)
6. The detected parameters are stored and the unit is ready for
use
1 MOTOR
(NO LIMIT SWITCHES AND SENSOR OF OBSTACLES IS
DISABLED)
ATTENTION: in this case the limits of the run must be signalled
with a START order
1. The door is closed until the unit
receives a START order
2. An opening manoeuvre is
carried out, the operation ends
when the unit receives a START
order
3. A closing manoeuvre is carried
out, the operation ends when
the unit receives a START order
4. The detected parameters are stored and the unit is ready for
use
- 22 -

Publicité

Table des Matières
loading

Table des Matières