V2 CITY1-EVO Guide Rapide page 28

Masquer les pouces Voir aussi pour CITY1-EVO:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
PARAMETER
VALUE
Ch.AU
no
0.5" - 20.0'
StoP
no
ProS
invE
Fot1
no
APCh
Fot2
CFCh
Ch
no
CoS1
no
APCh
AP
CoS2
no
APCh
Ch
DESCRIPTION
Automatic closing
Function deactivated
The gate closes after the setup time
Stop Input
The input STOP is not available
The input STOP stops the gate: pressing the command START the gate
continues the motion
The command STOP stops the gate: at the next START the gate starts
moving in the opposite direction
Photocell 1 input
This menu allows enabling the input for type 1 photocells, that is to
say, photocells active both during the opening and closing phase
Input disabled
Input enabled
Photocell 2 input
This menu allows enabling the input for type 2 photocells, that is to
say, photocells non active during the opening phase
Input enabled even at standstill gate too
Input enabled for the closing phase only
m
WARNING: If the photocell is damaged the gate is opened
anyway.
Before closing the test of the photocell (if enabled) will detect
the fault and prevent the gate from closing.
Input disabled
Safety edge 1 input
This menu allows enabling the input for type 1 safety edge, that is to
say, fixed edges
Input disabled
Input enabled in opening and closure
Input enabled during the opening and disabled during the closure
Safety edge 2 input
This menu allows enabling the input for type 2 safety edge, that is to
say mobile edges
Input disabled
Input enabled in opening and closure
Input enabled during the closing and disabled during the opening
- 26 -
AntE SCor
MEMO
no
no
no
no
no
no
CFCh CFCh
no
no
no
no

Publicité

Table des Matières
loading

Table des Matières