6.2.1 Coaxial pipe

A coaxial pipe can be used to expel the flue gases
and at the same time withdraw combustion air.
To achieve this:
• Connect a coaxial pipe (A) given that the stove
is already factory configured for this type of in-
stallation (Fig. 14)
It being understood that it is the technician's
responsibility to properly size the chimney
flue based on the installation situation and the
product, it is nonetheless recommended not
to exceed a length of 7 metres with an 8/13 cm
coaxial pipe.
A
004778570 - 11/11/2020
ITALIANO
ENGLISH
Fig. 14
DEUTSCH
6.2.2 Single wall pipe and air intake in room
In this case the combustion air will be taken from
the room.
To achieve this:
• Insert the aesthetic ring support (A) (supplied
with and placed inside the combustion cham-
ber during transport).
• Connect the flue gas pipe (B) (Fig. 15)
B
A
FRANÇAIS
ESPAÑOL
Fig. 15
51