PREPARING THE PLACE
OF INSTALLATION
5.1

General considerations

The following paragraphs contain some guide-
lines to be followed to obtain the maximum
efficiency of the product purchased and to
ensure safe operation. The following indications
are however subject to compliance with any
possible national, regional and municipal laws
and regulations in force in the country where the
appliance is installed.
In Italy, installation must be performed by quali-
fied personnel in compliance with the EN 10683
standard.

5.2 Safety Precautions

The operations for assembly and disassembly of
the appliance are reserved for specialist techni-
cians only.
It is recommended to be sure of their qualifica-
tions and their actual capacity.
For Italy, these technicians must be in
possession of the letter "C" qualifica-
tion issued by the chamber of com-
merce based on the Ministerial Decree.
37/08.

5.3 Place of installation

For the minimum distances that must be respect-
ed when positioning the appliance with respect
to flammable materials and objects, refer to the
Product booklet delivered as an attachment with
the appliance.
Floors made of flammable material such as wood,
parquet, linoleum, laminate or floors covered
with carpets must be protected by a fireproof
base under the appliance that also protects the
front during cleaning from any falling burning
residues.
The manufacturer declines all responsibility for
any variations in the characteristics of the mate-
rial constituting the floor under the protection.
Set up an accessible technical space
for any maintenance work.
Remember to respect the minimum distance
from flammable materials (X), shown on the
identification plate of the pipes used to make the
chimney (Fig. 6).
46
Pi = Flammable wall
Pp = Floor protection
Vedi libretto
See product
prodotto
booklet
Pi
in allegato
attached
Set up the electricity supply line to arrive near the
appliance for the connection of the power cable.

5.4 Combustion air

The appliance, during its operation, requires
combustion air.
The inflow of combustion air can be obtained in
the following ways:
• it can come directly from outside with direct
connection to the combustion chamber (Fig.
7 - Fig. 8).
• it can come from the installation room or suita-
ble adjacent rooms (Fig. 9)
Pi
X
Pp
Fig. 6