Technical Data - Bosch PLL 1 P Notice Originale

Masquer les pouces Voir aussi pour PLL 1 P:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
OBJ_BUCH-1735-005.book Page 18 Wednesday, July 13, 2016 12:01 PM
18 | English
11 Laser viewing glasses*
12 Tripod*
13 Wall holder
14 Metal surface for line operation
15 Metal surface for point operation
16 Adjusting screw of wall holder
17 1/4" tripod mount of wall holder
18 Serial number
* The accessories illustrated or described are not included as standard delivery.

Technical Data

Point and line laser
Article number
Working range to approx.
1)
– Line Operation
– Point Operation
2)
Levelling Accuracy
3)4)
Laser line width
– at a distance of 1.5 m
– at a distance of 5 m
Operating temperature
Storage temperature
Relative air humidity, max.
Laser class
Laser type
Batteries
Operating time, approx.
Weight according to EPTA-Procedure 01:2014
Dimensions (length x width x height)
1) when using the wall holder 13; under unfavourable conditions such as intense sun irradiation, the
working range is smaller
2) when the measuring tool is positioned correctly (see "Positioning the Measuring Tool", page 20)
3) at 25 °C
4) The width of the laser line depends on the surface characteristics and on the ambient conditions.
The measuring tool can be clearly identified with the serial number 18 on the type plate.
1 609 92A 1Y5 | (13.7.16)
PLL 1 P
3 603 F63 300
5 m
20 m
±0.5 mm/m
<2 mm
<4 mm
+5 °C...+40 °C
–20 °C...+70 °C
90 %
2
635–650 nm, <1 mW
2 x 1.5 V LR3 (AAA)
15 h
0.14 kg
154 x 24 x 30 mm
Bosch Power Tools