Measuring range (typical):
Measuring accuracy (typical)
Lowest indication unit
Indirect Distance Measurement and Vial
Measuring range
Angle Measurement
Measuring range
Measuring accuracy (typical)
Lowest indication unit
General
Operating temperature
Storage temperature
Relative air humidity, max.
Laser class
Laser type
Laser beam diameter at 77 °F
(25 °C) approx.
– at 33 ft (10 m) distance
– at 165 ft (50 m) distance
Weight
Dimensions
2610050658 01-18 GLM50C.indd 14

Technical Data

-14-
3601K72C10
6 in – 165 ft (0.15
– 50 m)
A
±1/16 in (±1.5 mm)
±1/32 in (0.5 mm)
0°–360° (4 x 90°)
0°–360° (4 x 90°)
±0.2°
C,D,E,
0.1°
+14 °F to 113 °F
(-10 °C to 45 °C)
-4 °F to 158 °F
(-20 °C to 70 °C)
90 %
2
635 nm, <1 mW
4/11 in (9 mm)
1-3/4 in (45 mm)
0.22 lb (0.1 kg)
4.2 x 1.8 x 0.9 in
(106 x 45 x 24
mm)
B
F