Safety information:

The maximum ozone quantity of 50 mg/hour per pump must not be exceeded.
-
The air passage can be reduced as a result of dust deposits in the ozonizer. This can
-
result in an increase in the water level in the skimmer, which - in extreme cases - can
overflow. To avoid this, check the ozonizer regularly to make sure that there are no
deposits of dust. If necessary, clean it.
Never breathe in free ozone.
-
The ozonizer may not be directly connected to the air valve or silencer.
-
In order to avoid water damage, the ozonizer must be placed high enough to ensure
-
that no water can penetrate it when the skimmer pump is switched off.
If the skimmer is used with new water it is common to find an excessive quantity of small
bubbles and often the skimmer cup fills with a clear liquid. This is due to the high surface
tension of the new water which prevents the bubbles from bursting. Once the water
matures this effect will go away but it can take up to 2-3 weeks. The effect is different on
different salt brands and is often dependant on levels of conditioning agents added to the
salt. Once these are skimmed out then the skimmer will act normally.
Heavier feeding in the initial stages will give the chemically pure water something to react
with and allow it to mature into proper aquarium salt water rather than the initial chemical
soup which is new salt water.
Dimensions / mm
technical
data
TC Serie
Footprint height
TC 1000ix
270x200
TC 1500ix
380x230
TC 2000i
395x270
TC 2000ix
405x270
TC 3000i
440x318
TC 3000ix
450x318
TC 6000i
460x382
TC 6000ix
470x382
TC 9000i
630x460
TC 9000ix
650x470
TC 12000i
780x530
TC 12000ix
800x550
Installation and removal from the Impeller, only ix: page 34
Fresh salt water

Technical Data

Aquarium size
Height
under
litre
outlet
pipe
535
251
600-1000
585
253
1000-1500
585
281
1500-2000
585
281
1500-2000
585
270
2000-3000
585
270
2000-3000
660
265
3000-6000
660
265
3000-6000
780
280
6000-9000
780
280
6000-9000
780
280
9000-12000
780
280
9000-12000
Spare part list from page 28
Wather flow
Power
rate
Recommended
Consumption
litre / h
Watt
1000
12
1700
22
2500
34
2500
33
3600
34
3600
33
4000
2 x 34
4000
2 x 33
9000
3 x 34
9000
3 x 33
12000
4 x 34
12000
4 x 33
-12-
Connections Ø /
Air
mm
Litre / h
Feedline
Outlet
600
20
1200
25
1900
32
1700
32
1900
32
1700
32
3800
32
3400
32
5700
40
5100
40
7600
40
6800
40
32
40
50
50
50
50
50
50
63
63
63
63

Publicité