2 operating modes are proposed:
B
asic
The appliance follows the setpoint temperature adjusted at all times.
P
roG
- The appliance follows the internal program defined for each day of
the week. The following ranges are defined when the appliance is
switched on:
Monday to Friday, comfort from 5am to 9am and from 5pm
to 11pm
Saturday and Sunday, comfort from 5am to 11pm.
You may modify these ranges and define 3 Comfort temperature rang-
es per day.
During these Comfort ranges, the temperature setpoint is adjusted
using
or
Outside the Comfort ranges, lowering the temperature is set in "Low-
er ECO T°" Prog mode (see chapter "The menu in PROG mode").
- The appliance follows your installation's external programming orders
(see the manual for your programming unit).
An On/Off switch is located at the rear of the device's unit.
Use the switch for extended shutdowns only
(excluding heating periods).
Set the switch (located at the rear of the appliance) to I to switch the
appliance on. When the appliance is switched off, you may need to set
the day and time again.
SWITCHING THE APPLIANCE ON / OFF
To shut down the appliance, press and hold
Confirm "Switch off" by pressing
To switch the appliance on, press and hold
DESCRIPTION OF THE MODES
.
THE SWITCH
.
.