MS660
➤ Connect the red cable to a cable to a permanent +12 volt charge (terminal +30).
The cable must be fused with at least a 1 A fuse.
If the gas detector is also to be switched to the alarm system as the main alarm,
connect both the relay contacts as follows:
➤ Connect the relay contact 1 (1) to earth (terminal 31).
➤ Connect the relay contact 2 (2) to the grey/white cable of MS660.
9

Performing a functional test

9.1
Testing the hand-held transmitter
➤ Test all of the switching functions with both hand-held transmitters.
If the system does not respond to a hand-held transmitter, program the hand-held
transmitter concerned (see chapter "Learning the hand-held transmitter, electronic
key and radio sensors/reading the PIN code" on page 46).
I
NOTE
The range of the hand-held transmitter can be restricted by solid metal
parts and strong electrical fields. It is usually between 10 m and 20 m.
9.2
Checking the central locking
If you activate the alarm system (see chapter "Activating MagicSafe" on page 43),
MagicSafe should lock the vehicle if central locking has been connected.
When you deactivate the alarm system (see chapter "Deactivating MagicSafe" on
page 44), MagicSafe should unlock the vehicle.
If you have programmed software function 11 ("Locking/unlocking with ignition"),
MagicSafe should lock the central locking approx. 5 sec. after the ignition is turned
on when the doors are closed. After the ignition is turned off, MagicSafe unlocks the
central locking again.
If the central locking is not working properly, proceed as follows:
➤ Check the electrical connection to the central locking.
➤ Check whether your vehicle supports software function 3 "Signal duration of the
door locking contacts" (see chapter "Programming" on page 41).
➤ Check which value has been set for software function 3.
EN