Installation through the roof
Kind of gas
length of duct A
(min. – max.)
Natural gas
1,0 – 10,0 m
Propane
1,5 – 10,0 m
All measures are excluding the length of the transit through the roof.
Installation through the roof with a bend
Kind of gas
length duct B
(min. – max.)
Natural gas 1,0 – 10,0 m
Propane
1,0 – 10,0 m
A1+A2 : B > 2:1
The ratio between vertical length and horizontal length (or 45° up) is always
at least 2 to 1.
All measures are excluding the length of the transit through the roof.
Sealing
at least 3.0 m Ø50 mm
at least 3.0 m Ø50 mm
length duct A1
length ducts A1 + A2
(min. – max.)
(min. – max.)
1,0 – 10,0 m
1,0 – 10,0 m
1,0 – 10,0 m
1,0 – 10,0 m
Sealing
No
No