Removing The Bain Marie, Pasta Cooker Water Drain Cover Panel; Installing The Gas/Water Supply/Drain Lines - Salvis VisionPro Série Notice De Montage

Masquer les pouces Voir aussi pour VisionPro Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Screw M4x10, hexagon
socket WAF 2.5 mm, art. no.
4.1.5

Removing the bain marie, pasta cooker water drain cover panel

Hexagon screws M5x10,
WAF 8 mm, art. no. 003743
4.2

Installing the gas/water supply/drain lines

This work is only necessary if the top and base units were separated.
D Supply and drain lines must not be in direct contact with heat sources (e.g. oven). The lines
must be installed with sufficient spacing to the heat source.
. Connect the water drain of the installation module to the ball valve.
. Connect the water supply hoses to the ball valve/mixer tap.
. Install the water drain hoses from the top unit/drain tap to the installation compartment with
downward gradient.
. Install the gas supply lines from the top unit to the installation compartment.
Assambly instruction Cooking station
Installing the connection between top and base units
02221807
Screw on handle
Removing the generator cover panel
. Remove the screw.
. Release the cover panel at the bottom.
Air flow
D After connecting all electric supply lines,
re-attach all removed cover panels.
D Improper air flow leads to overheating and
failure of the induction generators.
. Remove the screw on the handle.
. Remove the handle.
. Remove the screws on the cover panel.
D Support the cover panel when removing
the last screw.
. Remove the cover panel.
41 / 72