Proper Use - Ingersoll Rand ENL 100 Instructions De Montage Et De Service

Valve draineur
Table des Matières

Publicité

Caution!
Malfunctions in the application!
Through incorrect installation and insufficient maintenance, the ENL can malfunction. Condensate
which is not discharged can lead to damage to plants and in manufacturing processes.
Measures:
• Fail-safe condensate discharge directly optimises the compressed-air quality.
• To prevent damage and failures, it is imperative
• To comply with the provisions regarding proper use and with the operating parameters of the ENL in connection with
the case of application (see chapter "Proper use").
• To strictly adhere to the installation and operating advice in these instructions.
• To maintain and check the ENL at regular intervals in accordance with the advice in these operating instructions.

Proper use

• The ENL is an electronically level-controlled condensate drain for compressed-air plants.
• It is employed within the permissible operating parameters (see "Technical data").
• The ENL is able to drain condensate under operating pressure from the plant components virtually without compressed-air
losses.
• For its function, the ENL 100 requires an operating voltage and an operating pressure (see "Technical data").
• As far as the employment in plants with increased demands on the compressed-air quality is concerned (food industry, medi-
cal technology, laboratory equipment, special processes etc.), the operator must decide on measures for the monitoring of
the compressed-air quality. These have an effect on the safety of the subsequent processes and may prevent damage to
persons and plants.
• It is the task of the operator to ensure that the indicated conditions are met during the entire operating time.
• For the employment in CO
• The ENL and the condensate supply line need to be protected against frost, as otherwise the function cannot be guaranteed.
Ingersoll Rand also offers suitable products for this purpose.
Exclusion from the field of application
• The ENL as a condensate drain alone cannot guarantee a defined compressed-air quality, for this purpose, other additional
technical devices are required.
• ENL 100 is not suitable for use in plants carrying vacuum or atmospheric ambient pressure or in hazardous areas.
• The ENL must not be exposed to permanent direct solar or thermal radiation.
• ENL 100 must not be installed and operated in areas with an aggressive atmosphere.
ENL 100
plants, a ENL with a CO specification (ENL ... CO) must be used.
2
http://www.ingersollrandproducts.com
3