4. INDICATIONS FOR THE FINAL USER

THE CARD IS POWER OFF
The card is with no voltage alimentation: led, keys and the displays are off.
THE CARD IS POWER ON
When the card is powered up goes to STAND-BY status.
STAND-BY
In this status the card is powered up. All the displays and led aren‟t lighted and relè are not excited.
By pressing the ENCODER (10) the card goes to STOP mode.
STOP
In this status the card is ready to set up and starting of a cooking cycle.
User‟s interface is made of 3 functions directly accessibles: PHASE (7), MANUAL HUMIDITY (9, led 5) and START/STOP(8, led 6)
and 4 functions accessibles by encoder: TEMPERATURE (3), TIME (2), HUMIDITY (1) e PROGRAMS (4).
When there are no alarms and is set up a cycle, if you press START/STOP (9) the cooking cycle will start and the card will pass to
START mode.
By a long pressing of START/STOP (8) key, the card goes to STAND BY status.
In STOP mode on display you may visualize the chamber‟s temperature (except when you are in set up mode or when you are
visualizing a setpoint (time, chamber, humidity).
By rotating or pressing the encoder the TIME led begins to blink (2) and if you going on rotating the encoder (10) the blinking led will
run the 4 functions that you may enter by using encoder (10).
The display shows the set for the 3 functions (temperature, time and humidity) and the code of the carrying out programme for the
function „‟programs‟‟.
By pressing the encoder (10) you may select the function underlined by the blinking led.
After a timeout of 5 sec of inactivity you go out of the encoder‟s function selection mode.
If an alarm is present you may see this showed on display: a code will appear on display and a buzzer sounds. At the first pression of
a key the buzzer stops to sound.
The card returns in STAND-BY mode after a inactivity of 10 minutes.
COOKING CYCLES
Every cooking cycle (manual or program) may be made up of maximum 3 phases; each one needs 3 set values: temperature, time
and humidity. If a program is active it is underlined by the led PROGRAMS (4). Leds‟ number (7 a: 1-2-3) phases lighted shows the
number of phases of the selected cycle and the blinking phase‟s led (7) shows the actual phase.
HUMIDITY led (1) lighted means a set up humidity different from 0; on the contrary the led will be switched off.
In every starting (passage from STANDBY to STOP) the oven remembers the last manual saved cycle.
At the first starting, the default manual cycle is defined by a phase with a chamber‟s pre-set defined by a parameter, cooking time with
no set up and humidity in inactive mode; you can‟t start this cycle because needs of the time set up and this is a user‟s operation. At
the first starting attempt the buzzer produce a low sound ("boop") to communicate that the action is not possible.
TEMPERATURE SET UP
You have to rotate the encoder (10) until you light the led of TEMPERATURE (3) function. The display shows the actual set of
blinking temperature. By pressing the encoder (10) the display begins to blink and the LED (3) remains lighted to indicate that you
are changing the set of temperature.
By rotating the encoder (10) you may change the temperature‟s set up value between two limits defined by a parameter and by
pressing the encoder you‟ll confirm the selected value.
By rotating the encoder (10) until the beginning of the scale you may select a pause‟s phase identified by the writing „‟PAU‟‟ visualized
on he display.
After an inactivity of 5 sec timeout, you‟ll go out the temperature‟s set modifiying and you‟ll come back to the encoder‟s selection
function (only the led blinks) not confirming the selected value.
TIME SET UP
To set up cooking time you have to select TIME (2) function.
The display shows the set of cooking time in h.mm, selecting between 0.01 and 9.59; if cooking time is infinite the display shows
"Inf", while if the time is not set up , for example default cycle left during the last cooking and remained in the new starting or creation
of a new phase, the display shows "---".
By pressing the encoder(10) the display begins blinking and the LED remains lighted, to indicate that you are modifying the cooking
set time.
Starting from the beginning of the scale (complete anti-clock wise rotation) and after rotating the encoder (10) in clock-wise you‟ll run
the followings set up: "---", "Inf" and after, the times from 0.01 to 9.59. The running is cyclic, after 9.59 it comes back to "---".
By pressing the encoder (10) you‟ll confirm the selected value; after an inactivity timeout of 5 sec you go out of the temperature‟s set
up change coming back to the function of the selection by encoder (10) (only the led blinks) not confirming the selected value.
HUMIDITY SET UP (ONLY IN COMBINED CONVECTION AND DIRECT STEAM INJECTION OVENS)
With the encoder (10) runs until you alight HUMIDITY (1) function so the relative led begins to blink: on display you can visualize the
humidity set. By pressing the encoder (10) the display begins to blink and the led remains lighted : it means that you are modifying
humidity‟s set. By rotating the encoder (10) is possible to select a value between 0 e 10 and confirm by pressing the encoder (10).
After a timeout af inactivity of 5 sec you go out of the set temperatures‟ changes and you come back to the function selection of the
encoder (only the led blinks) not confirming the selected value.
COOKING PHASES
Every cooking cycle (manual or program) may be made up of maximum 3 phases. The number of the leds of the phases lighted
shows the number of phases of the selected program (with the phases of pause and those with cooking time not set up) and the
blinking phase‟s led (7) shows the actual phase visualized. The selected phase can be changed by pressing the key PHASES (7); if
you aren‟t in selection by encoder and press the key PHASES (7) the display shows for 3 seconds the time‟s set (and the light of the
LED TIME 2), in order to show the eventual phases with no set time.
Every time you press for long time the key PHASES (7) you add a new phase after the blinking one and the new added phase
becomes the actually blinking and selected one. The phases that follow the selected one move of a position in order to create a place
for the new phase. It isn‟t possible to create a new phase after the third. If there are already 3 phases the new one will erase the third.
The added phases have a chamber‟s preset defined by a parameter, not set up the cooking time and inactive humidity.
The cooking phases without a set up cooking time aren‟t executed in START so you have to pass to the following set up phase; a
cooking cycle can start when it has at least a time set up cooking phase.
To erase the actual phase, you have to select the TIME (2) function and rotate the encoder (10) until the beginning of the scale so
you can visualize "---"; if you confirm by pressing the encoder this value the selectetd phase will be erase. The following phases move
back of a position in order to take the vacant place; if you set up the time in this way "---", for the time of a cycle made of one phase,
this phase will be not erase but the cycle doesn‟t start until a set up of a valid phase.