DEPRESSION.
CONVECTOR
MOTOR
DISCONNECTED.
EXTRACTION
MOTOR
DISCONNECTED.
ENDLESS
MOTOR
DISCONNECTED.
ELECTRODE
(START-UP
RESISTANCE)
DISCONNECTED.
CONVECTOR MOTOR IN
SHORT-CIRCUIT.
SHORT-CIRCUIT
OF
THE
EXTRACTION MOTOR.
ENDLESS MOTOR SHORT-
CIRCUIT.
there is a failure in the air Redding system
necessary for combustion to happen.
The
Unicontrol
does
Convector.
The Unicontrol does not detect the Extractor.
The Unicontrol does not detect the reduction
motor of the endless motor.
The Unicontrol does not detect the start-up
Electrode (start-up resistance).
The Unicontril detects that the convector or
the
output
voltage
of
corresponding to the convector is in short-
circuit.
The Unicontrol detects that the Extractor of
tension
outlet
of
corresponding to the extractor is in short-
circuit.
The Unicontrol detects that the reduction
motor or tension output of the Unicontrol
corresponding to the reduction motor is in
short-circuit.
Gas outlet pipe stacked. Clean gas outlet.
Stove
maintenance.
Air entrance pipe stacked. Clean air Entrance
pipe.
Air reading pipe (transparent silicone pipe
linking the Unicontrol to the air inlet pipe),
disconnected or cut. Connect or replace.
Extractor does not turn.
Failure in depression reading system of the
Unicontrol, check depression air level, cf.
Menu 3, chapter 1 (S.A.T.)
If the stove is new, this might be due to
electric power problems.
not
detect
the
Check the convection motor is connected to
power through menu 3 section 0.
Check the grey cable going out from the
Unicontrol. Connect it if necessary.
If the stove is new, this might be due to
electric power problems.
Check is power is being supplied to the
exhaust motor through menu 3 section 1.
Check the red cable going out from the
Unicontrol. Connect it if necessary.
If the stove is new, this may be due to
electrical problems.
Check if the endless motor is connected to
power, see menu 3 section 2.
If power does not reach the endless motor,
check-with the stove disconnected- if the
safety thermostat is activated. Reactivate if
necessary.
If the stove is new, this might be caused by
electrical problems.
Make sure power reaches the start-up
resistance, see menu 3 section 3.
Check the black cable going out from the
Unicontrol. Connect it if necessary.
If the stove is new, this might be caused by
electrical problems.
Check with a multimeter if the motor is
the
Unicontrol
clamped to earth or the winding is in short-
circuit. Make sure power reaches the
convection motor, see menu 3 section 0.
Check the grey cable going out from the
Unicontrol. Connect it if necessary.
If the stove is new, this might be caused by
electrical problems.
Check with a multimeter if the motor is
the
Unicontrol
clamped to earth or the winding is in short-
circuit.Make
convection motor, see menu 3 section 1.
Check the red cable going out from the
Unicontrol. Connect it if necessary.
Make sure power reaches the endless motor,
see menu 3 section 2.
Check with a multimeter if the motor is
clamped to earth or the winding is in short-
circuits.
Check the blue cable going out from the
46
full
of
ash
inside.
Carry
sure
power
reaches
out