6.
PROBLEMS AND RECOMMENDATIONS.
6.1.
Do not turn the stove on and off successively because this might damage the electronical components and
motors ~230/240V - 50Hz.
6.2.
Do not touch the stove while your hands are wet. Though the stove is equipped with ground plug, it remains
an electric machine that could cause electric discharge if handled incorrectly. A qualified technician only shall
resolve the eventual problems.
6.3.
Do not remove any screw of the zones exposed to high temperature before they have been lubricated
properly with lubrication oil.
THE STOVE REMAINS OUT OF POWER:
6.4.
Make sure the stove is connected and the plug is leading power.
6.5.
Make sure the cable is not damage or cut.
While the stove is disconnected, dismantle the right door of the stove and check if any lead of the C.P.U. is
slack.
6.6.
Check the C.P.U. pilot. If it is OFF, check also the fuse on the C.P.U.
PELLETS DO NOT FALL AND THE STOVE DOES NOT TURN ON:
6.7.
Check if there are pellets in the hopper.
6.8.
Make sure the glass door is closed.
6.9.
Make sure the gas outlet tube is not obstructed by anything (e.g. bird nest, plastic, etc.).
6.10. Make sure the exhaust motor works, because if it does not work fuel will not fall.
6.11. If the reducer motor does not rotate and the displays indicate the pulses, the first thing to do will be unplug
the stove and verify if the security thermostat has been activated. With the stove unplugged, check that the
security thermostat is located inside the stove. For Ecoaire model (drawing 32) you can access to it if you
open the right side door by removing the two screws that fix it. To activate it, you must press the button. If
the thermostat is activated you will hear a "click". If the safety thermostat had been activated before, consult
your dealer. In the insert models Eco I and Eco II (drawing 33), it is situated in the frontal part, under the
keyboard. You must unscrew the stopper which protects it.
In Kerala model (drawing 34), you can access to it by opening the right side door.
The safety thermostat on the Córdoba stove is located in a similar place to that on the Kerala, reached
opening the housing door, above the door closure mechanism.