INSTALLATION MANUAL
DIGIWAY PLUS
This part is addressed to outward door installations
This part is addressed to outward door installations
1)
1)
Identify the dimensions of the motor, locate the fi xing position, the holes for the cables and the 6 fi xing holes making
Identify the dimensions of the motor, locate the fi xing position, the holes for the cables and the 6 fi xing holes making
use of the mounting template provided;
use of the mounting template provided;
2)
2)
Make sure that the bracket of the articulated arm falls in the right position;
Make sure that the bracket of the articulated arm falls in the right position;
3)
3)
Make 6 holes diameter Ø 8 mm and insert the 6 special plugs provided ;
Make 6 holes diameter Ø 8 mm and insert the 6 special plugs provided ;
4)
4)
Fix the plate to the wall using the special screws provided;
Fix the plate to the wall using the special screws provided;
5)
5)
Fix the motor to the mounting plate with the screws M6x14 provided
Fix the motor to the mounting plate with the screws M6x14 provided
6)
6)
Fix the bracket to the door referring to the distance A of the table below;
Fix the bracket to the door referring to the distance A of the table below;
7)
7)
Plug in the articulated arm on the motor shaft and screw the fi xing screw M6;
Plug in the articulated arm on the motor shaft and screw the fi xing screw M6;
8)
8)
If the distance between the motor and the door is higher than that allowed, use the extension (
If the distance between the motor and the door is higher than that allowed, use the extension ( optional
9)
9)
Fix the arm to the motor by using the screw M6x14 or M6x70 provided;
Fix the arm to the motor by using the screw M6x14 or M6x70 provided;
10)
10)
Make all the electrical connections;
Make all the electrical connections;
11)
11)
Apply power;
Apply power;
12)
12)
Follow the procedure : «Getting started»;
Follow the procedure : «Getting started»;
13)
13)
Connect the Ground wire to the cover terminal and fi x the cover.
Connect the Ground wire to the cover terminal and fi x the cover.
L1
L3
Speed
Parameter
(mm)
A A
410
410
B B
270
270
A - B
A - B
140
140
C C
40
40
L1
L1
70,5
70,5
L2
L2
300
300
L3
L3
130 - 300
130 - 300
L2
Power
Description
(mm)
430
430
Door hinge – door bracket distance
Door hinge – door bracket distance
360
360
Door hinge – motor axis distance
Door hinge – motor axis distance
70
70
Motor axis – door bracket distance
Motor axis – door bracket distance
Bracket holes distance
Bracket holes distance
Motor axis – wall distance
Motor axis – wall distance
Base lever
Base lever
Arm extension
Arm extension
A
B