CDVI DIGIWAY PLUS DWP 102 Série Manuel D'installation page 24

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
DIGIWAY PLUS
Follow the set-up
Follow the
set-up procedure hereunder both 2 x single motors
procedure hereunder both 2 x single motors ( DWPSxx )
This can be completed only if the mechanical and electrical installations have been executed.
This can be completed only if the mechanical and electrical installations have been executed.
1
Move to pos. "0" the external switches of both units.
Move to pos. "0" the external switches of both units.
Open completely the MASTER leaf and leave it open.
Open completely the MASTER leaf and leave it open.
2
Close the SLAVE leaf.
Close the SLAVE leaf.
Verify that the safety inputs
Verify that the safety inputs ( terminals 5-6-7 )
photocells ( FTC and FTC-S) and that the LED's
photocells ( FTC and FTC-S) and that the LED's L3 and L4 are stable on.
Using the keyboard or using the 4ch transmitter memorized on the unit SLAVE, set temporarily the unit of the door SLAVE in
Using the keyboard or using the 4ch transmitter memorized on the unit SLAVE, set temporarily the unit of the door SLAVE in
3
ONE DOOR confi guration [ default value ].
ONE DOOR confi guration [ default value ].
Follow the Door CALIBRATION procedure, corresponding to the STEP III, described at pag. 37 of this manual, up to the end,
Follow the Door CALIBRATION procedure, corresponding to the STEP III, described at pag. 37 of this manual, up to the end,
4
and leave the door CLOSED.
and leave the door CLOSED.
Close the MASTER leaf.
Close the MASTER leaf.
5
Verify that the safety inputs ( terminals 5-6-7 )
Verify that the safety inputs
photocells ( FTC and FTC-S) and that the leds L3 and L4 are stable on.
photocells ( FTC and FTC-S) and that the leds
Using the keyboard or using the 4ch transmitter memorized on the unit SLAVE, set temporarily the unit of the door SLAVE in
Using the keyboard or using the 4ch transmitter memorized on the unit SLAVE, set temporarily the unit of the door SLAVE in
6
ONE DOOR confi guration [ default value ]. NOTE:
ONE DOOR confi guration [ default value ].
other devices must be connected only to this unit.
other devices must be connected only to this unit.
Follow the Door CALIBRATION procedure, corresponding to the STEP III, described at pag. 37 of this manual, up to the end,
Follow the Door CALIBRATION procedure, corresponding to the STEP III, described at pag. 37 of this manual, up to the end,
7
The door remains OPEN
The door remains OPEN. .
Set the ENGAGE POSITION: it is the point ( in case of overlapping doors ) where the 2 leaves are free to open and close
Set the ENGAGE POSITION: it is the point ( in case of overlapping doors ) where the 2 leaves are free to open and close
8
without any interference . Always keeping the external switch in position
without any interference . Always keeping the external switch in position "0" in both the motors, enter in the menu DOOR
CALIBRATION of the SLAVE unit and select the option DOOR ENGAGE POSITION.
CALIBRATION of the SLAVE unit and select the option DOOR ENGAGE POSITION.
Move manually the leaves, looking for the minimum position, next to the close, where the SLAVE door is free to move without
Move manually the leaves, looking for the minimum position, next to the close, where the SLAVE door is free to move without
9
clashing with the MASTER, in both the manoeuvres opening and closing. Press OK.
clashing with the MASTER, in both the manoeuvres opening and closing. Press OK.
Repeat the actions of the steps 8 and 9 for the MASTER door, moving the leaf MASTER up to fi nd the minimum position, next to
Repeat the actions of the steps 8 and 9 for the MASTER door, moving the leaf MASTER up to fi nd the minimum position, next to
10
the close, where the leaf MASTER is free to open and close, without clashing the SLAVE.
the close, where the leaf MASTER is free to open and close, without clashing the SLAVE.
NOTE : The engage value set for the MASTER can be equal or greater the the one set for the SLAVE.
NOTE
: The engage value set for the MASTER can be equal or greater the the one set for the SLAVE.
Enter in the CONFIGURATION menu of the
Enter in the CONFIGURATION menu of the SLAVE
11
NUM. DOORS
NUM. DOORS
2 DOORS OVERLAP
2 DOORS OVERLAP
DOOR TYPE
DOOR TYPE
Enter in the CONFIGURATION menu of the MASTER
Enter in the CONFIGURATION menu of the
12
NUM. DOORS
NUM. DOORS
2 DOORS OVERLAP
2 DOORS OVERLAP
DOOR TYPE
DOOR TYPE
Move both the external switches to position "I" : the 2 doors close very slowly.
Move both the external switches to position "I" : the 2 doors close very slowly.
13
The procedure is over.
The procedure is over.
cdvi.com
24
cdvigroup.com
Part III : Final set-up
Part III : Final set-up
( DWPSxx ) and for a double door unit
( terminals 5-6-7 ) of the SLAVE unit are shorted or connected to the corresponding safety
of the SLAVE unit are shorted or connected to the corresponding safety
L3 and L4 are stable on.
( terminals 5-6-7 ) of the MASTER unit are shorted or connected to the corresponding safety
of the MASTER unit are shorted or connected to the corresponding safety
L3 and L4 are stable on.
NOTE: The
The MASTER makes the reference for the double door : the radars and the
Door Calibration
Door Engage Pos.
Slave
Slave
SLAVE unit and set the following parameters:
unit and set the following parameters:
= TWO DOORS
= TWO DOORS
= ENABLE
= ENABLE ( only if there is door leaf overlap )
( only if there is door leaf overlap )
= SLAVE
= SLAVE
MASTER unit and set the following parameters:
= TWO DOORS
= TWO DOORS
= ENABLE
= ENABLE ( only if there is door leaf overlap )
( only if there is door leaf overlap )
= MASTER
= MASTER
and for a double door unit ( DWPDxx)
MASTER makes the reference for the double door : the radars and the
"0" in both the motors, enter in the menu DOOR
Door Engage Pos.
022
|||||||||||||||||......................
unit and set the following parameters:
( DWPDxx). .
Master
Master
EN

Publicité

Table des Matières
loading