INSTALLATION MANUAL
DIGIWAY PLUS
DIGIWAY PLUS is equipped with an innovative software which fi ts the internal parameters to the door characteristics. The calibration sets
DIGIWAY PLUS is equipped with an innovative software which fi ts the internal parameters to the door characteristics. The calibration sets
the door travel limits and launches a special 5 cycles routine for the automatic detection of the door characteristics.
the door travel limits and launches a special 5 cycles routine for the automatic detection of the door characteristics.
For the calibration follow the next steps:
For the calibration follow the next steps:
NOTE : Before proceeding with the calibration check the connection of the battery red/black cable to the main board and disconnect tem-
porarily the magnetic lock ( when used ).
Action
Action
Set the EXTERNAL SWITCH in position '0'
1
1
'0' = DOOR FREE
(*)
Select Door Calibration from the Main
2
2
Manu and press OK
Select Door Limits from the submenu of
3
3
Door Calibration and press OK
4
4
CLOSE THE DOOR COMPLETELY and
press OK
OPEN THE DOOR COMPLETELY and
5
5
press OK
(*)
(*) : It is advisable to open the door 10 cm more of the fi nal position desired
6 6
Select Autocalibration from the Door Cali-
bration Menu and press OK
Press OK: the door begins 5 cycles of
7 7
opening and closing until asking for
SAVE
8
8
Press OK. The calibration cycle is over.
The door remains open
Set the EXTERNAL SWITCH in position 'I'
9
9
= AUTOMATIC. The door closes and the
calibration is completed.
STEP III: DOOR CALIBRATION [ SINGLE LEAF ]
(*) If this set is not followed, the software will give a warning.
Display
Display
Door Calibration
Door Calibration
Door Limits
Set Door Limits
Wizard
Close Door
Then Press OK
Open Door
Then Press OK
Thank You
Door Calibration
Door Limits
Door Calibration
Autocalibration
Autocalibration
Wizard
Proceed with
Autocalibration?
Closing ...
Measure 1/5...
Tm= XX,X V= XX
Save ?
....C...........................
P=000,0 V=00,0
Warning : whilst the Digiway is
going trough its 5 learning cycles,
as it opens very quickly, it is
dangerous the passage across the
door.