INSTALLATION MANUAL
DIGIWAY PLUS
Main Functions
O.D. Type
Sets the obstacles detection criteria
Sets the reaction time against an
O.D. Reactivity
obstacle
Please contact your local offi ce for further infomation regarding Obstacle Detection (O.D.)
DIGIWAY PLUS is equipped with many further parameters (all adjustable) to fi t better to any type of installation. From the main menu select
DIGIWAY PLUS is equipped with many further parameters (all adjustable) to fi t better to any type of installation. From the main menu select
ADVANCED SET to enter this submenu, which allows more adjustments.
ADVANCED SET to enter this submenu, which allows more adjustments.
Advanced Setting
1) 1)
Electrolock Time
Advanced Setting
2) 2)
Opening Jolt Time
Advanced Setting
3) 3)
Open Jolt Torque
Advanced Setting
4) 4)
Open Delay
Advanced Setting
5) 5)
Wind Stop Torque
STEP IV: ADJUSTMENTS (continued...)
STEP IV: ADJUSTMENTS (continued...)
Description
C1+C2+C3
C1+C2+C4
C1+C2+C3+C4
0,1 - 5 sec.
STEP V: ADVANCED SETTINGS
Electrolock Time
0,5 SEC.
|||||||||||||||||...................
Opening Jolt Time
0,5 SEC.
|||||||||||||||||...................
Open Jolt Torque
20%
|||||||||||||||||.....................
Open Delay Time
0,5 SEC.
|||||||||||||||||...................
Wind Stop Torque
10%
|||||||||||||||||......................
Value
By default the motor detects an obstacle when the speed becomes
almost zero (C1) and the current increases over a preset threshold (C2).
The criteria C3 intervenes after the speed decreases under 2/3 of the
max speed, and causes the door to stop.
C1+C2
C3 is not active during the current calculus cycles.
The criteria C4 intervenes if the current consumed exceeds 175% of the
current consumed during the preset.
According to the type of door (resistance, balance, weight, width etc) it is
possible to adjust the reaction of the door against an obstacle.
The fi rst 2 criteria are always present. It is possible to add the criteria C3
or C4 or both.
Default value = C1+C2.
Use the UP or DOWN keys to adjust this time : the higher the value,
the longer will be the contact of the door against the obstacle (less
sensitive).
Default value = 0,1 Sec.
It is possible to pause the electrolock release time from 0,1 to 40 sec. depending on the
It is possible to pause the electrolock release time from 0,1 to 40 sec. depending on the
lock/door type . Press the UP or DOWN buttons to increase or decrease the pause time
lock/door type . Press the UP or DOWN buttons to increase or decrease the pause time
and confi rm with OK.
and confi rm with OK.
Default value = 0,5 Sec
Default value = 0,5 Sec
The opening jolt, when enabled, is a short closing motion before the operator begins
The opening jolt, when enabled, is a short closing motion before the operator begins
opening - this relieves pressure of "side-load" for some locking devices. It's possible to
opening - this relieves pressure of "side-load" for some locking devices. It's possible to
adjust this time from 0,1 to 40 sec. depending on the type of electrolock and door.
adjust this time from
0,1 to 40 sec. depending on the type of electrolock and door. Press
the UP or DOWN buttons to increase or decrease the time and confi rm with OK.
the UP or DOWN buttons to increase or decrease the time and confi rm with OK.
Default value = 0,5 Sec
Default value = 0,5 Sec
It is possible to adjust the torque of the motor during the opening jolt pulse.
It is possible to adjust the torque of the motor during the opening jolt pulse.
This is adjusted depending on the mechanical resistance of the door. Press the UP or
This is adjusted depending on the mechanical resistance of the door. Press the
DOWN buttons to increase or decrease the value and confi rm with OK.
DOWN buttons to increase or decrease the value and confi rm with OK.
Default value = 20%.
Default value =
20%.
It is possible to add a short delay to the door motion to allow the electrolock bolt to
It is possible to add a short delay to the door motion to allow the electrolock bolt to
exit completely from its keeper, ensuring the door is fully unlocked. This can be useful
exit completely from its keeper, ensuring the door is fully unlocked. This can be useful
when using motorised locks. The open delay is set by pressing UP or DOWN buttons to
when using motorised locks. The open delay is set by pressing
increase or decrease from
increase or decrease
from 0,1 to 40 sec
0,1 to 40 sec and confi rm with OK
Default value = 0,5 Sec
Default value = 0,5 Sec
LOCK
LOCK
Delay
Delay
MOTOR
MOTOR
START
START
It is possible to adjust the torque of the motor when the wind stop utility is enabled. This
It is possible to adjust the torque of the motor when the wind stop utility is enabled. This
allows changing the value of the force applied by the door related to the wind pressure.
allows changing the value of the force applied by the door related to the wind pressure.
Press the UP or DOWN buttons to increase or decrease the torque and confi rm with
Press the UP or DOWN buttons to increase or decrease the torque and confi rm with
OK.
OK.
Default value =
Default value = 50%.
50%.