Safety Considerations; Technical Data - Dustcontrol DC 2800c/Auto Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17

Safety Considerations

Read all instructions before attempting to operate this
machine and save these instructions.
Warning! When using electric machines, basic safety
precuations should always be
risk of fi re, electric shock and personal injury, including
the following:
1.
Work area environment
Don´t expose the machine for rain. Don´t use it in
damp or wet locations or in presence of fl ammable
liquids or gases.
2.
Overload
Never let the machine operate fully throttled. Always
follow the regulations pertinent to the
material you are working with ie asbestos. Don´t use
the machine for purposes that it isn´t
intended for.
3.
Body injuries
Never let the suction come in contact with parts of
the body. Th e strong suction eff ect can
hurt the blood-vessels in the skin. Don´t repair the
electric components yourself, get some-body quali-
fi ed. Faults may cause injury. See also below under
warnings.

TECHNICAL DATA

HxWxL
Weight
Inlet
Hose length
Collecting sack
Flow, max
Neg. pressure, 115/230 V, max
Power consumption vacuum producers 1200/1400 W
115/230 V
Auto: Power consumption connected tool */ min 200 W
Fine fi lter polyester, area
Degree of separation
(EN 60335-2-69, Class M)
Filter area, microfi lter H13
Degree of separation, microfi lter
(EN 1822-1)
(EN 60335-2-69, Class H)
Sound level
4.
followed to reduce the
5.
6.
7.
8.
1070x420x510 mm
14 kg
Ø 50 mm
5 m
20 l
3
190 m
/h
21/24 kPa
max 230 V/10 A: 1200 W
230 V/16 A: 2200 W
120 V/20 A: 1200 W
1.5 m
2
99.9 %
2
0.85 m
HEPA H13
99.995 %
< 68 dB(A)
DC 2800c/Auto, 9
Don´t abuse cord
Never pull the machine by cord. Keep cord from
heat and sharp edges. Check the electric cable regu-
larly if damage.
Important measure
With cleaning and maintenance on the machine,
the power cable should be dis-connected from the
supply.
Maintain the machine with care
Keep machine clean and check that the hose is enti-
red and that all gaskets are tight. Follow instructions.
Keep handles dry and free from oil and grease.
Checking of damage
Before futher use of the machine it should be care-
fully checked that the machine is unda-maged. If
there are any damaged parts these should be repaired
by of a Dustcontrol authori-zed service center.
Warning
Use only accessories and replacable parts which are
available in Dustcontrol catalogue.
Vacuum producer
capacity
kPa
20
15
10
1200 W
5
0
50
*/ Always check with local regulations.
1400 W
100
150
200 m
3
/h
Part No 94112/94116

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

9411294116

Table des Matières