Velleman DVM901 Mode D'emploi page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
Pollution
Only nonconductive pollution occurs. Occasionally,
degree 2
temporary conductivity caused by condensation is to be
expected. (home and office environments fall under this
category)
Pollution
Conductive pollution occurs, or dry nonconductive pollution
degree 3
occurs that becomes conductive due to condensation that is
to be expected.
(industrial environments and environments exposed to
outside air - but not in contact with precipitation)
Pollution
The pollution generates persistent conductivity caused by
degree 4
conductive dust or by rain or snow. (exposed outdoor
environments and environments where high humidity levels
or high concentrations of fine particles occur)
Warning: This device was designed in accordance with EN 61010-1
pollution degree 2. This implies that certain restrictions in use apply that
are related to pollution which can occur within the environment of use. Refer
to the table above.
This device is only suitable for measurements in Pollution
degree class 2 environments.
9. Specifications
This device is not calibrated when purchased!
Regulations concerning environment of use:
Use this meter only for measurements in CAT I, CAT II, CAT III and CAT IV
environments (see §7).
Use this meter only in a pollution degree 2 environment (see §8).
Ideal working conditions include:
temperature: 0 °C to 40 °C (32 °F to 104 °F)
relative humidity: max. 80 % RH
altitude: max. 2000 m (6560 ft)
voltage.............................................................................. 700 V
fuse protection
F0.5 A/1000 VDC, 6.75 x 33 mm
F15 A/1000 VDC, 6.75 x 33 mm
power supply ....................................................... 1 x 3.7 V (incl.)
display ............................................................ LCD, 40000 counts
ranging mode .......................................................... auto/manual
continuity buzzer ................................................................... yes
diode test ............................................................................. yes
low-battery indication ............................................................ yes
data hold .............................................................................. yes
backlight .............................................................................. yes
V. 02 – 29/01/2020
DVM901
8
©Velleman nv

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cat ii 700 vCat iv 600 vDvm903 cat ii 700 vDvm903 cat iv 600 v

Table des Matières