Inconveniences Causes; Störungen Ursache - Gis GS35/500/600 Instructions D'emploi

Table des Matières

Publicité

8.

INCONVENIENCES CAUSES

Each electrocompressor is assembled and meticolously tested in our
factory before being shipped and very rarely it will show inconveniences or
breakages. In any case, the following table resumes the main causes for
the inconveniences which could be found and the remedies for finding a
solution.
Tab. 8-1
Anomalies
Possible causes
Wrong direction of
Inversion of phases.
rotation.
The compressor
Loss of current.
starts or stops during
work for no obvious
reason.
Intervention of the
thermal relay.
Compressor or motor
Wrong direction of
overheating.
rotation.
insufficient aeration.
Frequent startings.
Excessive
Decrease in
consumptions.
productivity.
Suction filters are
clotted.
Seals are not tight.
Belt sliding.
Valve break-up.
Loss of air from
The no-return valve is
pressure switch or
worn out or the
electrovalve.
sealing disk is dirty so
that air comes in from
the tank.
The compressor
The pipe connecting
keeps sucking air but
the valve to the
pressure does not
pressure switch
rise.
overheats and comes
out of its fitting.
Jeder Elektromotor wurde genau im Werk montiert und kollaudiert bevor
dieser versandt wird und es ist daher unwahrscheinlich das jener deffekt
oder fehlerhaft ist.
Trotzdem stellen wir nachstehend eine zusammenfassende Aufstellung
der wichtigsten auftretenden Fehler, die auftreten können, auf sowie deren
notwendigen Schritte zur Behebung.
Tab. 8-1
Remedies
Störungen
Invert two cables
Fehlerhafte
inside the electric
Drehrichtung.
socket.
Der Kompressor kann
Check the electric
nicht eingeschalten
socket.
werden, oder bleibt
ohne Motive stehen.
Check if the unit is
locked then push on
the reset button.
Call for a skilled
electrician.
See above.
Überhitzung des
Clean the cooling air
Kompressors oder
ducts and improve
Motor.
the environment.
Reduce
consumptions.
Regelmässiges
Clean the suction
Anlassen.
filter.
Nachlassen der
Leistungsfähigkeit.
Close the fittings.
Tension or replace
belts.
Call for a skilled
technician
Unscrew the
hexagonal head (A) of
Luftverlust vom
the valve.
Druckschalter oder
Clean its housing.
Elektroventil.
Clean or replace the
rubber disk (B).
Reassemble
meticolously (fig.
8-1).
Call for a skilled
technician.
Der Kompressor lädt
kontinuierlich Luft auf
und der Druck nimmt
nicht ab.
8.
STÖRUNGEN URSACHE
Mögliche Ursachen
Phasenverwechslung Man vertauscht die 2
Stromstärke fehlt.
Eingriff Wämeschutz.
Drehrichtung falsch.
Unausreichende
Lüftung.
Hoher Verbrauch.
Verstopfung Filter.
Verlust an den
Verbindungen.
Rutschen des
Riemens.
Zerstörung Ventil.
Rückhalteventil da
verstopft oder
abgenutzt auf der
Rückhaltescheibe,
lässt nicht die Luft
zurück in den Tank.
Verbindungsrohr
Ventil-Druckschalter
erhitzt sich und löst
sich ab.
Abhilfe
Phasen
Man kontrolliert den
Elektroanschluss.
Kontrollieren der
Kontrolleuchte
Blockierung und
drückt Knopf der
Wiederherstellung.
Eventüll lässt man
einen Elektriker
kontrollieren.
Siehe oben.
Man reinigt die
Durchgänge der Luft
und verbessert die
Raumbedingungen.
Verringert Konsum.
Reinigen des
Ansaugfilters.
Anziehen der
Verbindungen.
Spannen oder
Auswechseln des
Riemens.
Technischer Eingriff.
Lösen des
sechseckigen Kopfes
A des Ventiles,
reinigen des Sitzes.
Reinigen oder
Auswechseln der
Gummischeibe B.
Genaues Montieren
(Bild 8-1)
Technischer Eingriff
49

Publicité

Table des Matières
loading