Electronic self-diagnosis

The circuit boards perform continuous self-
diagnosis. In the event of hardware faults or
malfunctions in the circuit board that could
be dangerous for the end user, the device will
assume "safe" mode, the solenoid valves are
deactivated and the display shows the relative
fault code.
Generally, the default operating parameters
are restored by disconnecting and recon-
Fault type
Single burner locked out
Spurious flame / flame
detection circuit fault on
single burner
Main valve control circuit fault
Reference voltage circuit fault
Watchdog circuit fault
Microcontroller ports fault
Eeprom fault
Valve drive circuit fault
Max 5 resets in
15 minutes exceeded
Supply circuit fault
Resonator fault / Generic fault
All burners locked out
Control logic communication
errors
Touch panel control error
88
necting the power supply. This action will re-
solve most problems.
If the fault persists, contact your nearest ser-
vice centre.
Fault types and codes are shown in the follo-
wing table.
Displayed
fault code
b
F
FLt00
FLt01
FLt02
FLt03
FLt04
FLt05
FLt06
FLt08
FLt09
FLt0A
FLt0C
FLt0E
Solution
Perform reset procedure as described in
previous sections.
Disconnect electrical power supply and then
reconnect after a few seconds.
If the problem persists, contact the service
centre.
Perform reset procedure as described in
previous sections.
Disconnect electrical power supply and then
reconnect after a few seconds.
If the problem persists, contact the service
centre.
Perform reset procedure as described in
previous sections.
Perform reset procedure as described in
previous sections.
Disconnect electrical power supply and then
reconnect after a few seconds.
If the problem persists, contact the service
centre.