Minimum flow adjustment (4-burner version)

The minimum flow is correctly adjusted when the flame remains lit without a pot on the pan sup-
port in position 1 of the burner control.
To adjust the minimum flow of each burner, proceed as follows:
Press the "+" and "-" buttons simultaneously for approx. 3 seconds as shown in the figure above.
"MIN" will appear on the display indicating the activation of the adjustment procedure.
At this stage, select the burner to be adjusted using the "+" and "-" buttons. By pressing these
buttons repeatedly, a LED will light up showing the selected burner.
To confirm the selected burner, press the timer button.
The selected burner will light on the minimum setting. To increase or decrease the minimum flow,
use the "+" and "-" buttons of the specific burner.
During the adjustment procedure, the selected burner display will show "-" if the set minimum level
corresponds to the factory setting.
^ or v will flash on the display if the flow rate is respectively higher or lower than the preset flow
rate.
To go to the next burner, repeat the procedure from the second figure.
After adjusting all the burners, press the timer button again to exit the procedure. The minimum
flow settings are saved and will be used each time you use the appliance.