Faults and fault rectification

If faults should occur, check them using the following table:
Fault
The green indi­
cator light does
not illuminate
when switched
on.
The appliance
does not heat up
and both yellow
indicator lights
are off.
If the fault cannot be rectified:
‒ switch off the appliance and disconnect from the mains,
‒ do not open the housing,
‒ contact the authorised Customer Service agent.
26 / 64
Possible cause
Main switch before appliance
not turned on.
There is no power supply at
all.
Mains fuse on site has
tripped.
For example, the appliance
has been overheated due to
heating when dry.
The temperature limiter has
switched off the heating ele­
ment.
Remedy
Turn on main switch.
Inform the power supply company.
Possible faults on the appliance must
be checked by an authorised Customer
Service agent.
Reset the circuit breaker.
Switch off the unit.
Wait until the appliance has cooled
down.
Pour water into the tank.
Reactivate the temperature limiter with
the reset button.
Switch on the appliance.
If the problem occurs again, have the
appliance checked by authorized cus­
tomer service.
Screw cap over reset
button for temperature limi­
ter