Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Helios Ventilatoren
MONTAGE- UND BETRIEBSVORSCHRIFT
INSTALLATION AND OPERATING INSTRUCTIONS
NOTICE DE MONTAGE ET D'UTILISATION
Zentrales Lüftungsgerät
Central ventilation unit
Unité de ventilation centrale
KWL 170 W
KWL 170 W ET
Kompaktes Wandgerät mit Wärmerückgewinnung
und EC-Technik
Compact wall-mounted unit with heat recovery
and EC technology
Centrale murale compacte avec récupération de chaleur
et technologie EC
DE
EN
FR
easy
Controls 3.0

Publicité

Table des Matières
loading

Sommaire des Matières pour Helios KWL 170 W

  • Page 1 Controls 3.0 Zentrales Lüftungsgerät Central ventilation unit Unité de ventilation centrale KWL 170 W KWL 170 W ET Kompaktes Wandgerät mit Wärmerückgewinnung und EC-Technik Compact wall-mounted unit with heat recovery and EC technology Centrale murale compacte avec récupération de chaleur...
  • Page 2: Table Des Matières

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET INHALTSVERZEICHNIS MONTAGE- UND BETRIEBSVORSCHRIFT KAPITEL 1 SICHERHEIT ................................. SEITE 3 Grundlegende Hinweise ................................. Seite 3 Warnhinweise ..................................Seite 3 Sicherheitshinweise ................................Seite 3 Einsatzbereich ..................................Seite 4 Personalqualifikation ................................Seite 4 KAPITEL 2 GRUNDLEGENDE HINWEISE ............................
  • Page 3 Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET DEUTSCH KAPITEL 7 BEDIENUNG ................................SEITE 24 Bedienungsmöglichkeiten ..............................Seite 24 7.1.1 Lokaler Webserver ................................Seite 24 7.1.2 easyControls Cloud-Dienst ..............................Seite 24 7.1.3 Bedienelement ................................... Seite 24 7.1.4 Gebäudeleittechnik (GLT) ..............................Seite 24 Geräteeinstellungen über easyControls 3.0 .........................
  • Page 4: Grundlegende Hinweise

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET KAPITEL 1 Grundlegende Hinweise Zur Sicherstellung einer einwandfreien Funktion und zur eigenen Sicherheit sind alle nachstehenden Vorschriften genau SICHERHEIT durchzulesen und zu beachten. Die national einschlägigen Normen, Sicherheitsbestimmungen und Vorschriften (z.B.
  • Page 5: Einsatzbereich

    Einsatzbereich – Bestimmungsgemäßer Einsatz Das zentrale Lüftungsgerät KWL 170 W/W ET mit Wärmerückgewinnung, ist für die zentrale Be- und Entlüftung von Wohnhäusern und Etagenwohnungen konzipiert. Das Gerät ist zur Förderung normaler oder leicht staubhaltiger (Parti- kelgröße < 10 µm), wenig aggressiver und feuchter Luft, in gemäßigtem Klima und im Bereich seiner Leistungskennlinie geeignet.
  • Page 6: Transport

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET KAPITEL 2 Transport Das Gerät ist werkseitig so verpackt, dass es gegen normale Transportbelastungen geschützt ist. Der Transport muss GRUNDLEGENDE sorgfältig durchgeführt werden. HINWEISE Bei Weiterversand, vor allem über längere Distanzen (z.B. Seeweg) ist zu prüfen, ob die Verpackung für Transportart und -weg geeignet ist.
  • Page 7: Vorschriften Und Richtlinien

    Alle Ausführungen der zum Gerät gehörenden Dokumentationen müssen beachtet werden, sonst entfällt die Gewähr- leistung. Gleiches gilt für Haftungsansprüche an den Hersteller. Der Gebrauch von Zubehörteilen, die nicht von Helios empfohlen oder angeboten werden, ist nicht zulässig. Even tuell auftretende Schäden unterliegen nicht der Gewährleistung.
  • Page 8: Geräteübersicht

    Der Wärmebereitstellungsgrad ist von den Faktoren Luftfeuchtigkeit und dem Temperaturunterschied zwischen Außen- und Abluft abhängig. Geräte mit Enthalpie-Wärmetauscher (KWL 170 W ET) gewinnen neben der Wärme auch Feuch- tigkeit aus der Abluft zurück, die den Räumen mit der Zuluft wieder zugeführt wird.
  • Page 9: Technische Daten

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET Bei Verwendung eines Heizregisters, muss das Rohrsystem 0,5 m vor und nach dem Heizregister mit temperaturbeständigem bzw. nicht brennbarem Rohr versehen werden (z.B. Wickelfalzrohr) Abb. 2 Abluft Abb. KWL 170 W Zuluft ...
  • Page 10: Abmessungen

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET Abmessungen Abb. 3 132 163 143 Abluft Fortluft ø125 Zuluft Außenluft Kugelsiphon ø125 ø12 Betriebspunkte Zuluft Maße in mm Schalldaten 3.6.1 Schallleistung Gehäuseabstrahlung Abb. 4 Betriebspunkte KWL 170 W/W ET Gehäuseabstrahlung...
  • Page 11: Schallleistung Zu- Und Abluft

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET riebspunkte Zuluft Betriebspunkte Zuluft 3.6.2 Schallleistung Zu- und Abluft Abb. 5 Abb. 6 Betriebspunkte KWL 170 W/W ET Betriebspunkte KWL 170 W/W ET Zuluft Abluft Betriebspunkte Zuluft Betriebspunkte Abluft Druck...
  • Page 12: Schallleistung Fort- Und Außenluft

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET riebspunkte Zuluft Betriebspunkte Zuluft 3.6.3 Schallleistung Fort- und Außenluft Abb. 7 Abb. 8 Betriebspunkte KWL 170 W/W ET Betriebspunkte KWL 170 W/W ET Fortluft Außenluft Betriebspunkte Außenluft Betriebspunkte Fortluft Druck...
  • Page 13: Einbauhinweise

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET KAPITEL 4 Einbauhinweise 4.1.1 Positionierung MONTAGE Das Gerät ist zur Installation innerhalb der Wohneinheit bzw. des Gebäudes, an der Wand oder zum Einbau in einen Schrank, vorgesehen. Aufgrund der Betriebsgeräusche wird empfohlen, das Gerät in einem Nebenraum (z.B. Wasch- raum, Technikraum oder Abstellraum) zu installieren.
  • Page 14: Gerät Montieren

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET Für den Umbau des Gerätes wie folgt vorgehen: Verletzungsgefahr durch Herunterfallen der Gerätetür bzw. -rückwand sowie des Wärmetauschers! WARNUNG Die Gerätetür bzw. -rückwand kann beim Abnehmen bzw. der Wärmetauscher beim Herausnehmen herunterfallen und schwere Verletzungen verursachen.
  • Page 15: Kugelsiphon Montieren

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET Kugelsiphon montieren Während der Heizperiode kann es durch den Prozess der Wärmerückgewinnung, im Wärmetauscher zur Bildung von Kondensat kommen. Das Kondensat muss frei aus dem Gerät ablaufen können. Hierzu muss der beiliegende Kugelsi- phon (Lieferumfang) in der Bodenwanne des Gerätes montiert werden.
  • Page 16: Lüftungsleitungen Anschließen

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET 6. Kondensatschlauch (Länge max. 1,5 m) an das Entwässerungssystem des Gebäudes anschließen (s. Abb. 22). Abb. 22 Kondensatschlauch DN 12 mm (Gefälle beachten!) 7. Kugelsiphon kontrollieren: – Um die Dichtheit zu gewährleisten, darf der Kugelsiphon bei bauseitiger Montage keinen seitlichen Belastungen durch den Kondensatschlauch ausgesetzt sein! –...
  • Page 17: Anschlussplan

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET 5.1.1 Anschlussplan Abb. 23 KWL-VOC eC Externes Modbus Sensor* Art. Nr.: 20247 KWL-BE Touch 2x2x0,5 mm A+ B- Art. Nr.: 20245 ws KWL-FTF eC 2x2x0,5 mm 2x2x0,5 mm Sensor* Art. Nr.: 20249...
  • Page 18: Verdrahtungsplan

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET 5.1.2 Verdrahtungsplan Abb. 24 MB_A MB_A MB_B MB_B +24V +24V RS_A RS_A RS_B RS_B siehe SS-1433 +24V RS_A +24V RS_A RS_B RS_B +11V1 +24V AN/I D/I1 +24V RM/I D/I2 RM/O...
  • Page 19: Erstinbetriebnahme

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET KAPITEL 6 Erstinbetriebnahme Für die Erstinbetriebnahme muss das Gerät ordnungsgemäß an das Stromnetz angeschlossen bzw. mit dem Stromnetz INBETRIEBNAHME verbunden sein. Anschließend kann der Inbetriebnahmeassistent über den lokalen Webserver oder optional über das Bedienelement KWL-BE Touch (Zubehör) durchgeführt werden.
  • Page 20: Einregulierung

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET Abb. 27 4. Gerät konfigurieren und auf „Weiter“ klicken. > Die Zusammenfassung der Einstellungen öffnet sich. 5. Einstellungen prüfen und ggf. anpassen. 6. „Zurück“ klicken, um die Einstellungen anzupassen. 7. „Fertig“ klicken, um die Erstinbetriebnahme abzuschließen.
  • Page 21 Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET Abb. 28 Abb. 29 Kennlinie KWL 170 W Kennlinie KWL 170 W Zuluft Abluft 10 % â 10 % â 20 % ê 20 % ê 30 % ô 30 % ô...
  • Page 22 Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET 2. Über die Software easyControls 3.0 oder das Bedienelement KWL-BE Touch für die Ventilatorleistungen folgende Wer- te im jeweiligen Lüftungsprofil hinterlegen: Unterwegs: 30 % / Zuhause: 50 % / Intensivlüftung: 80 % (vgl. Abb. 33).
  • Page 23 Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET Ventilatorleistungen ermitteln: 1. Volumenströme aus der Auslegungsberechnung für die drei Lüftungsprofile „Zuhause“, „Unterwegs“ und „Intensiv- lüftung“ in die Kennlinie des Gerätes für Zu- und Abluft eintragen (vgl. Abb. 36). ⓘ Wir empfehlen folgende Werte in den Lüftungsprofilen zu hinterlegen: •...
  • Page 24: Volumenstrommessung Zur Einregulierung Der Anlage (Feinjustierung) Durchführen

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET 5. Unter „Ventilatoreinstellung“ die Ventilatorleistungen für Zu- und Abluft gemäß der ermittelten Werte für die Nenn- lüftung eintragen (vgl. Abb. 38). Abb. 38 6.3.3 Volumenstrommessung zur Einregulierung der Anlage (Feinjustierung) durchführen •...
  • Page 25: Kapitel 7 Bedienung

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET KAPITEL 7 Bedienungsmöglichkeiten 7.1.1 Lokaler Webserver BEDIENUNG Das Gerät kann über den lokalen Webserver mittels einem Webbrowser, über ein mobiles Endgerät (z.B. Notebook, PC, Tablet, Smartphone) konfiguriert werden. Es ist keine Anmeldung/Registrierung des Gerätes erforderlich.
  • Page 26: Filterwechsel

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET ZUHAUSE Lüftungsprofil bei Anwesenheit von Personen. Folgende Parameter sind einstellbar: • Ventilatorleistung • Zuluft Hier ist die Solltemperatur für die Zuluft einzustellen. ⓘ     O hne Nachheizung (optional; als Zubehör erhältlich) liegt die maximal erreichbare Solltemperatur 2-3 °C unter der Ablufttemperatur.
  • Page 27: Wochenprogramm

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET 7.2.1.7 Wochenprogramm Abb. 40 • Wochenprogramm ein-/ausschalten • Wochenprogramm erstellen/bearbeiten Durch Klicken auf ein Feld ändert sich das Lüftungsprofil in folgender Reihenfolge (vgl. Abb. 40): Lüftungsprofil „Zuhause“ (1x klicken) Lüftungsprofil „Unterwegs“ (2x klicken) Lüftungsprofil „Intensivlüftung“...
  • Page 28: Einstellungen

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET 7.2.4 Einstellungen 7.2.4.1 Sprache Gewünschte Sprache für die Benutzeroberfläche auswählen. 7.2.4.2 Freigabecode Freigabecode ändern. ⓘ Standardmäßig ist der Freigabecode 0000 voreingestellt. 7.2.4.3 Cloud-Dienst Gerät mit dem easyControls Cloud-Dienst verbinden oder Cloud-Dienst trennen. Beim Verbinden mit dem Cloud-Dienst öffnet sich die Startseite zur Anmeldung automatisch.
  • Page 29: Relais Einstellungen

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET • Not-Aus/Normalbetrieb (0 V / 24 V) • Intensivlüftung Aus/Ein (0 V / 24 V) • Normalbetrieb / Bypass (0 V / 24 V) • Wochenprogramm Aus / Ein (0 V / 24 V) •...
  • Page 30: Gerät Warten

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET KAPITEL 8 Gerät warten Das Gerät ist je nach Bedarf, jedoch mindestens einmal im Jahr auf Verschmutzungen und Verunreinigungen zu prüfen WARTUNG UND (Sichtprüfung). SERVICE Lebensgefahr durch elektrischen Schlag! Ein elektrischer Schlag kann zu Tod oder schweren Verletzungen führen.
  • Page 31: Wärmetauscher Warten Und Reinigen

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET Wärmetauscher warten und reinigen 8.3.1 Wärmetauscher warten Der Wärmetauscher ist je nach Bedarf oder mindestens einmal jährlich auf Verunreinigungen und Verschmutzungen zu prüfen (Sichtprüfung) und ggf. zu reinigen, s. Kapitel „8.3.2 Wärmetauscher reinigen“ auf Seite 30.
  • Page 32: Stilllegen Und Entsorgen

    Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET Verbrennungsgefahr durch heiße Oberflächen! WARNUNG Heiße Oberflächen können schweren Verbrennungen verursachen. > Gerät 5 Minuten abkühlen lassen bzw. warten, bis die Ventilatoren ausgedreht sind. Verletzungsgefahr durch rotierende Ventilatoren! WARNUNG Rotierende Ventilatoren können Gliedmaße verletzen und schwere Verletzungen verursachen.
  • Page 33 Montage- und Betriebsvorschrift Zentrales Lüftungsgerät – KWL 170 W/W ET...
  • Page 34 Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET TABLE OF CONTENTS INSTALLATION AND OPERATING INSTRUCTIONS CHAPTER 1 SAFETY ..................................PAGE 3 Basic information ..................................Page 3 Warning instructions ................................Page 3 Safety instructions .................................. Page 3 Area of application ..................................
  • Page 35 Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET ENGLISH CHAPTER 7 OPERATION................................PAGE 24 Operating options ................................. Page 24 7.1.1 Local web server ................................Page 24 7.1.2 easyControls cloud service ..............................Page 24 7.1.3 Control element .................................. Page 24 7.1.4...
  • Page 36: Basic Information

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET CHAPTER 1 Basic information In order to ensure correct operation and for your own safety, please read and observe the following instructions carefully SAFETY before proceeding. Relevant national standards, safety regulations and provisions (e.g. DIN EN VDE 0100) as well as the technical connection conditions of the energy supply company must be observed and applied.
  • Page 37: Area Of Application

    – Intended use The central ventilation unit KWL 170 W/W ET with heat recovery is designed for the central supply and extract venti- lation of residential houses and apartments. The unit is suitable for conveying normal or slightly dusty (particle size <...
  • Page 38: Shipping

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET CHAPTER 2 Shipping The delivery is packed ex works in such a way that it is protected against normal transport strain. The shipping must BASIC be carried out carefully.
  • Page 39: Regulations And Guidelines

    All versions of this documentation must be observed, otherwise the warranty shall cease to apply. The same applies to liability claims against the manufacturer. The use of accessory parts which are not recommended or offered by Helios is not permitted. Any possible damages are not covered by the warranty.
  • Page 40: Unit Overview

    The heat recovery efficiency depends on the factors of humidity and the temperature difference between intake and extract air. Units with enthalpy heat exchangers (KWL 170 W ET) recover humidity from the extract air in addition to heat, which is returned to the rooms through the supply air.
  • Page 41: Technical Data

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET Bei Verwendung eines Heizregisters, muss das Rohrsystem 0,5 m vor und nach dem Heizregister mit temperaturbeständigem bzw. nicht brennbarem Rohr versehen werden (z.B. Wickelfalzrohr) Fig. 2 Extract air Abluft Abb.
  • Page 42: Dimensions

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET Dimensions Fig. 3 132 163 143 Extract air Abluft Exhaust air Fortluft ø125 Supply air Intake air Zuluft Außenluft Kugelsiphon Ball siphon ø125 ø12 Betriebspunkte Zuluft Dimensions in mm Sound data 3.6.1 Sound power level Casing-radiated...
  • Page 43: Sound Power Level Supply And Extract Air

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET riebspunkte Zuluft Betriebspunkte Zuluft 3.6.2 Sound power level Supply and extract air Fig. 5 Fig. 6 Operating points KWL 170 W/W ET Operating points KWL 170 W/W ET...
  • Page 44: Sound Power Level Exhaust And Intake Air

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET riebspunkte Zuluft Betriebspunkte Zuluft 3.6.3 Sound power level Exhaust and intake air Fig. 7 Fig. 8 Operating points KWL 170 W/W ET Operating points KWL 170 W/W ET...
  • Page 45: Installation Instructions

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET CHAPTER 4 Installation instructions 4.1.1 Positioning INSTALLATION The unit is designed for installation on the wall inside the residential unit or building or for installation in a cabinet. Due to the operating noise, it is recommended to install the unit in a secondary room (e.g.
  • Page 46: Install Unit

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET Proceed as follows to modify the unit: Risk of injury due to the unit door/back panel and the heat exchanger falling down! WARNING The unit door/back panel and the heat exchanger can fall down when removing and cause serious injuries.
  • Page 47: Install Ball Siphon

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET Install ball siphon During heating periods, condensate may form in the heat exchanger due to the heat recovery process. The condensa- te must be able to drain freely from the unit. The provided ball siphon (scope of delivery) must be installed in the base tray of the unit for this purpose.
  • Page 48: Connect Ventilation Ducts

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET 6. Connect condensate hose (length max. 1.5 m) to the building drainage system (see Fig. 22). Fig. 22 Condensat hose DN 12 mm (note gradient!) 7. The ball siphon must be inspected: –...
  • Page 49: Connection Diagram

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET 5.1.1 Connection diagram Fig. 23 Modbus cable length: maximum 100 m tw isted pairs of w ires must be used. KWL-VOC eC Rem ote Sensor* monitoring art. nr.: 20247...
  • Page 50: Wiring Diagram

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET 5.1.2 Wiring diagram Fig. 24 MB_A MB_A MB_B MB_B +24V +24V RS_A RS_A RS_B RS_B SS-1433 +24V RS_A +24V RS_A RS_B RS_B +11V1 +24V AN/I D/I1 +24V RM/I...
  • Page 51: Initial Commissioning

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET CHAPTER 6 Initial commissioning The unit must be properly connected or linked to the mains power supply for the initial commissioning. The commissio- COMMISSIONING ning assistant can then run via the local web server or optionally via the control element KWL-BE Touch (accessories).
  • Page 52: Adjustment

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET Fig. 27 4. Configure unit and click “Next”. > The settings summary page will open up. 5. Check settings and adjust if necessary. 6. Click “Previous” to adjust the settings.
  • Page 53 Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET Fig. 28 Fig. 29 Characteristic curve KWL 170 W Characteristic curve KWL 170 W Supply air Extract air 10 % â 10 % â 20 % ê 20 % ê...
  • Page 54 Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET 2. Enter the following values for the fan powers in the respective ventilation profile via the easyControls software or the control element KWL-BE Touch: Away: 30 % / At home: 50 % / Boost: 80 % (cf. Fig. 33).
  • Page 55 Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET Determine fan powers: 1. Enter the flow rates from the design calculation for the three ventilation profiles “At home”, “Away” and “Boost” in the unit characteristic curve for supply and extract air (cf. Fig. 36).
  • Page 56: Perform Flow Rate Measurement For Adjusting The System (Fine Adjustment)

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET 5. Enter the fan powers for supply and extract air according to the determined values for nominal ventilation under “Fan setting” (cf. Fig. 38). Fig. 38 6.3.3 Perform flow rate measurement for adjusting the system (fine adjustment) •...
  • Page 57: Operating Options

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET CHAPTER 7 Operating options 7.1.1 Local web server OPERATION The unit can be configured via the local web server using a web browser, via a mobile end device (e.g. notebook, PC, tablet, smartphone).
  • Page 58: Filter Replacement

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET AT HOME Ventilation profile in the presence of persons. The following parameters can be adjusted: • Fan power • Supply air The target supply air temperature is adjusted here.
  • Page 59: Weekly Programme

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET 7.2.1.7 Weekly programme Fig. 46 • Activate/deactivate weekly programme • Create/edit weekly programme The ventilation profile changes in the following order by clicking on a field (cf. Fig. 46): Ventilation profile “At home”...
  • Page 60: Settings

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET 7.2.4 Settings 7.2.4.1 Language Select the desired language for the user interface. 7.2.4.2 Release code Change release code. ⓘ The release code is pre-set to 0000 as standard.
  • Page 61: Relay Settings

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET • Intensive ventilation Off/On (0 V / 24 V) • Normal mode / Bypass (0 V / 24 V) • Weekly programme Off / On (0 V / 24 V) •...
  • Page 62: Unit Maintenance

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET CHAPTER 8 Unit maintenance The unit must be checked for contamination and dirt (visual inspection) as needed or at least every year. SERVICE AND Danger to life due to electric shock MAINTENANCE An electric shock can result in death or serious injuries.
  • Page 63: Heat Exchanger Cleaning

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET 8.3.2 Heat exchanger cleaning Danger to life due to electric shock DANGER An electric shock can result in death or serious injuries. > Before opening the unit, the unit must be fully isolated from the power supply.
  • Page 64: Standstill And Disposal

    Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET Risk of injury due to the panel or unit door falling down! WARNING The panel or unit door can fall down when removing and cause serious injuries. > Wear protective footwear.
  • Page 65 Installation and Operating Instructions Central ventilation unit – KWL 170 W/W ET...
  • Page 66 Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET SOMMAIRE NOTICE DE MONTAGE ET D‘UTILISATION CHAPITRE 1 SÉCURITÉ ................................... PAGE 3 Informations générales ................................Page 3 Consignes de sécurité ................................Page 3 Consignes de sécurité ................................Page 3 Domaines d‘utilisation ................................
  • Page 67 Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET FRANÇAIS CHAPITRE 7 COMMANDE ................................PAGE 24 Possibilités de commande ..............................Page 24 7.1.1 Serveur web local ................................Page 24 7.1.2 Service Cloud easyControls .............................. Page 24 7.1.3...
  • Page 68: Chapitre 1 Sécurité

    Filet à cheveux Le filet à cheveux empêche les longs cheveux de se coincer dans les pièces mobiles. Pour le fonctionnement, le raccordement et l’utilisation, contacter Helios en cas de doutes. Des informations supplémentaires sont consultables dans les normes et textes de loi.
  • Page 69: Domaines D'utilisation

    Domaines d‘utilisation – Usage prévu La centrale KWL 170 W/W ET avec récupération de chaleur est conçue pour la ventilation centrale des bâtiments résidentiels et des appartements. L‘appareil est adapté au transport d‘air normal ou légèrement pollué (taille des parti- cules <...
  • Page 70: Chapitre 2 Informations Générales

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET CHAPITRE 2 Transport L’appareil est emballé en usine et est protégé des dégâts de transport courants. Transporter l’appareil avec précautions. INFORMATIONS En cas de transport ultérieur, en particulier sur de longues distances (par exemple par mer), il faut vérifier si l‘emballage GÉNÉRALES...
  • Page 71: Normes - Règlementations

    Si toutes les consignes indiquées dans cette notice ne sont pas correctement respectées, la garantie s’annule. Idem pour les garanties constructeur Helios. L’utilisation d’accessoires, non fournis, non conseillés ou non proposés par Helios, est interdite. Tous changements ou transformations effectués sur l’appareil sont interdits, altèrent sa conformité...
  • Page 72: Chapitre 3 Informations Sur Le Produit

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET CHAPITRE 3 Vue d‘ensemble de l‘appareil INFORMATIONS Fig. 1 SUR LE PRODUIT              ...
  • Page 73: Données Techniques

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET Bei Verwendung eines Heizregisters, muss das Rohrsystem 0,5 m vor und nach dem Heizregister mit temperaturbeständigem bzw. nicht brennbarem Rohr versehen werden (z.B. Wickelfalzrohr) Fig. 2...
  • Page 74: Dimensions

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET Dimensions Fig. 3 132 163 143 air extrait Abluft Fortluft air rejeté ø125 air extérieur air soufflé Zuluft Außenluft Kugelsiphon Siphon à boule ø125 ø12 Betriebspunkte Zuluft Dimensions en mm Données acoustiques...
  • Page 75: Puissance Acoustique Air Soufflé Et Extrait

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET riebspunkte Zuluft Betriebspunkte Zuluft 3.6.2 Puissance acoustique air soufflé et extrait Fig. 5 Fig. 6 Points de fonctionnement KWL 170 W/W ET Points de fonctionnement KWL 170 W/W ET Air soufflé...
  • Page 76: Puissance Acoustique Air Rejeté Et Extérieur

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET riebspunkte Zuluft Betriebspunkte Zuluft 3.6.3 Puissance acoustique air rejeté et extérieur Fig. 7 Fig. 8 Points de fonctionnement KWL 170 W/W ET Points de fonctionnement KWL 170 W/W ET Air rejeté...
  • Page 77: Chapitre 4 Montage

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET CHAPITRE 4 Instructions d‘installation 4.1.1 Positionnement MONTAGE L‘appareil est destiné à être installé au mur ou dans une armoire à l‘intérieur de l‘appartement ou du bâtiment. En raison du bruit de fonctionnement, il est recommandé...
  • Page 78: Montage De L'appareil

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET Pour démonter l‘appareil, procéder comme suit : Risque de blessure dû à la chute de la porte ou du panneau arrière de l‘appareil ! AVERTISSEMENT La porte ou le panneau arrière de l‘appareil peuvent tomber lorsqu‘ils sont retirés et provoquer des blessures graves.
  • Page 79: Montage Du Siphon À Boule

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET Montage du siphon à boule Pendant la période de chauffe, des condensats peuvent se former dans l‘échangeur à contre-courant en raison du processus de récupération de la chaleur. Le condensat doit pouvoir s‘écouler librement de l‘appareil. Le siphon à boule (inclus dans la livraison) doit être monté...
  • Page 80: Raccordement Des Conduits De Ventilation

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET 6. Raccorder le tube des condensats (longueur max. 1,5 m) au système d’évacuation des eaux usées du bâtiment (à un siphon) (voir Fig. 22). Fig. 22 Tubes des condensats DN 12 mm (doit être en pente !)
  • Page 81: Schéma De Raccordement

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET 5.1.1 Schéma de raccordement Fig. 23 Longueur du câble Modbus : 100 m maximum Il faut utiliser des paires de f ils torsadés. KWL-VOC eC Surveillance à...
  • Page 82: Schéma De Câblage

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET 5.1.2 Schéma de câblage Fig. 24 MB_A MB_A MB_B MB_B +24V +24V RS_A RS_A RS_B RS_B voir SS-1433 +24V RS_A +24V RS_A RS_B RS_B +11V1 +24V...
  • Page 83: Chapitre 6 Première Mise En Service

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET CHAPITRE 6 Première mise en service Pour la première mise en service, l‘appareil doit être correctement raccordé au réseau électrique ou branché au secteur. PREMIÈRE MISE L‘assistant de mise en service peut ensuite être mis en place via le serveur web local ou, en option, via la commande...
  • Page 84: Paramétrages

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET Fig. 27 4. Configurer l‘appareil et cliquer sur „Suivant“. > Le récapitulatif des paramètres s‘ouvre. 5. Vérifier les paramètres et les ajuster si nécessaire. 6. Cliquer sur „Retour“ pour ajuster les paramètres.
  • Page 85 Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET Fig. 28 Fig. 29 Courbe caractéristique KWL 170 W Courbe caractéristique KWL 170 W Air soufflé Air extrait 10 % â 10 % â 20 % ê...
  • Page 86 Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET 3. Les uns après les autres et mesurer la pression différentielle statique entre l‘air rejeté et extrait puis entre l‘air soufflé et extérieur. 4. Entrer les pressions différentielles déterminées de la mesure de l‘air soufflé et extérieur dans la courbe caractéristique de l‘appareil pour l‘air soufflé...
  • Page 87 Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET Déterminer les performances du ventilateur : 1. Saisir les débits volumiques issus du l‘étude pour les trois profils de ventilation „Présent“, „Absent“ et „Forcé“ dans la courbe caractéristique de l‘appareil pour l‘air soufflé et extrait (voir Fig. 36).
  • Page 88: Réglage Par Mesure Du Débit Volumique (Réglage Fin)

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET 5. Sous „Réglage du ventilateur“, entrer les performances du ventilateur pour l‘air soufflé et extrait en fonction des valeurs déterminées pour la ventilation nominale (voir Fig. 38).
  • Page 89: Chapitre 7 Commande

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET CHAPITRE 7 Possibilités de commande 7.1.1 Serveur web local COMMANDE L‘appareil peut être configuré via le serveur web local à l‘aide d‘un navigateur web, via un appareil mobile (par exemple un ordinateur portable, un PC, une tablette, un smartphone).
  • Page 90: Remplacement Des Filtres

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET PRÉSENT Profil de ventilation en présence de personnes. Les paramètres suivants peuvent être définis : • Vitesse ventilateur • Définir température air neuf Ici, vous fixez la température de consigne pour l‘air d‘alimentation.
  • Page 91: Programme Hebdomadaire

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET 7.2.1.7 Programme hebdomadaire Fig. 40 • Activer/désactiver le programme hebdomadaire • Créer/modifier le programme hebdomadaire En cliquant sur un champ, le profil de ventilation change dans l‘ordre suivant (voir Fig. 40) Profil de ventilation „Présent“...
  • Page 92: Réglages

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET 7.2.4 Réglages 7.2.4.1 Langue Sélectionner la langue souhaitée pour l‘interface utilisateur. 7.2.4.2 Code d‘accès Changer le code d‘accès. ⓘ Le code d‘accès 0000 est préréglé par défaut.
  • Page 93: Réglages Des Relais

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET • Arrêt d‘urgence / fonctionnement normal (0 V / 24 V) • Ventilation intensive arrêt/marche (0 V / 24 V) • Fonctionnement normal / Bypass (0 V / 24 V) •...
  • Page 94: Chapitre 8 Entretien Et Maintenance

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET CHAPITRE 8 Entretien de l‘appareil L‘appareil doit être contrôlé en fonction des besoins, mais au moins une fois par an (inspection visuelle). ENTRETIEN ET Danger de mort par électrocution ! MAINTENANCE En choc électrique peut entraîner la mort ou des blessures graves.
  • Page 95: Entretien Et Nettoyage De L'échangeur À Contre-Courant

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET Entretien et nettoyage de l‘échangeur à contre-courant 8.3.1 Entretien de l‘échangeur à contre-courant L‘échangeur à contre-courant doit être inspecté selon les besoins ou au moins une fois par an pour détecter les salis- sures et l‘encrassement (inspection visuelle) et être nettoyé...
  • Page 96: Recyclage

    Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET Risque de brûlures en raison de surfaces chaudes ! AVERTISSEMENT Les surfaces chaudes peuvent causer de graves brûlures. > Laisser refroidir la centrale 5 min et attendre l’arrêt complet des ventilateurs.
  • Page 97 Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET...
  • Page 98 Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET...
  • Page 99 Notice de montage et d‘utilisation Unité de ventilation centrale – KWL 170 W/W ET...
  • Page 100 CH HELIOS Ventilatoren AG · Tannstrasse 4 · 8112 Otelfingen GB HELIOS Ventilation Systems Ltd. · 5 Crown Gate · Wyncolls Road · Severalls Industrial Park · Colchester · HELIOS Ventilatoren · Postfach 854 · Siemensstraße 15 · 6023 Innsbruck...

Ce manuel est également adapté pour:

Kwl 170 w et

Table des Matières