Charger source priority:
To configure the charging
16
source priority of the
battery
18
Alarm control
Auto return to the default
19
display screen
INFOSEC UPS SYSTEM - 4, rue de la Rigotière - 44700 Orvault - FRANCE - www.infosec-ups.com
Hot Line – Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)2 40 94 29 51 - hotline@infosec.fr – 06 15 AA 59 203 33
49V
51V
53V
55V
57V
If C3 MPPT / C3+ MPPT is working in Line, Standby or Fault
mode, the charging source can be programmed as below:
Solar first
Utility first
Solar and Utility
(Only available for
4000 and 5000
model)
Only Solar
If C3 MPPT / C3+ MPPT is working in Battery mode or in
Power saving mode, only the solar energy can charge the
battery. The solar energy will charge the battery if it is
available and sufficient.
Alarm on (default)
Return to the default
display screen
(default)
50V
52V
54V (default)
56V
58V
The solar energy will charge the
battery as the first priority.
The utility will charge the battery only
when the solar energy is not
available.
The utility will charge the battery as
the first priority.
The solar energy will charge the
battery only when the utility power is
not available.
The solar energy and the utility will
charge the battery at the same time.
The solar energy will be the only
charging source no matter if the utility
is available or not.
Alarm off
If selected, no matter if users switch
the display screen, it will automatically
return to the default display screen
(Input voltage /output voltage) after no
button is pressed for 1 minute.
20